Barracuda 2LP Installation Guide, Rev. E | 17 |
1Measured with an average reading DC ammeter. Instanta- neous +12V current peaks will exceed these values.
2A −10% tolerance is permissible during initial start of the spindle but must return to ±5% before reaching 7,200 RPM. The ±5% must be maintained after the drive signifies that its
3See the +12V current profile in the Barracuda 2LP Product Manual (publication number 83328930).
4This condition occurs when the Motor Start option is enabled and the drive has not yet received a Start Motor command.
5See “Conducted noise immunity” in the Barracuda 2LP Product Manual.The specified voltage tolerance is inclusive of ripple, noise, and transient response.
6At
7Minimum current loading for each supply voltage is not less than 4% of the maximum operating current shown.
8Use separate ground returns for +5 and +12V supplies.
9Where power is provided to multiple drives from a common supply, carefully consider
10Operating condition is a