Seagate ST136475LW/LC manual

Page 25

Barracuda 36 Installation Guide, Rev. B

23

ground (see Figure 12). The host device cannot override the SE jumper. If “DIFFSNS” is at nominal ground (0V to .6V), all of the bus receivers/drivers operate in single-ended mode. If “DIFFSNS” is between .7V and 1.9V, all bus receiver/drivers operate in low voltage differential (LVD) mode.

“LC” and “LW” models have a “wide” (16-bit) SCSI data bus rather than the standard (non-wide) 8-bit SCSI data bus; how- ever, you can use these wide drives on a standard (non-wide) 8-bit data bus. However, the unused lines must be terminated the same as the used lines.

Figures 3a and 3b show typical drive connections. The following tables list the maximum cable lengths and number of devices allowed on a daisy-chain cable for I/O data transfer rates shown.

Note. For LVD operation, twisted pair cables are recom- mended. For LVD Fast-40 operation, twisted pair cables are strongly recommended. For Fast-80 operation, twisted pair cables are required.

Image 25
Contents Barracuda Disc Drive ST136475LW/LC Contents Electrostatic discharge protection PrefaceImportant safety information and precautions Page Wichtige Sicherheitshinweise Page Barracuda 36 Installation Guide, Rev. B Electromagnetic susceptibility Regulatory agency complianceElectromagnetic compliance Australian C-Tick Electromagnetic compliance for the European UnionSeagate Technology support services Presales Support Customer Service CSO European Support Services Africa/Middle East Support Services SeaFAX General description RPM Drive characteristicsST136475LW/LC DC power requirements Amps, multimodeDimensions of the drive General information Drive modelsScsi ID jumpers Drive termination Circuits and data path widths Terminator powerPage Cable characteristics for single-ended I/O Circuits Cable characteristics for differential I/O circuits Sixty-eight pin connection to drive Multiple-drive connection to host adapter Drive model LC with single 80-pin I/O and power connector Providing adequate cooling Kü hlung des Systems Suggested air flow Abbildung 4. Empfohlener Luftstromverlauf Installation des Laufwerkes und Anschluß der Kabel Mounting the drive and connecting cablesPage DC power connector Abbildung 5. Gleichstromanschluß Hinweis Barracuda 36 Installation Guide, Rev. B Mounting configuration dimensions Quick reference desktop system notes Formatting the driveTerminating the drive Setting the Scsi ID jumpersSetting the Scsi ID on model LW drives Host Alternate Additional jumper options for LW drives Other applicable jumper optionsAdditional jumper option for LW drives LC drives Jumper options for LC drives Single-ended/low-voltage-differential selection Additional jumper option for LC drives Page