Seagate ST9100825A, ST980829A manual Acoustics, Electromagnetic immunity, Drive level acoustics

Page 20

2.11Acoustics

Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea- surements are consistent with ISO document 7779. Sound power measurements are taken under essentially free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.

Note. For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined by the following equation:

Number of seeks per second = 0.4 / (average latency + average access time)

Table 4: Drive level acoustics

Idle*

Performance Seek

 

 

2.4 bels (typ)

2.9 bels (typ)

2.6 bels (max)

3.1 bels (max)

 

 

*During periods of drive idle, some offline activity may occur, according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels.

2.12Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:

Table 5:

Electromagnetic immunity

 

 

 

 

 

 

 

 

 

 

Performance

Reference

Test

 

Description

level

standard

 

 

 

 

Electrostatic discharge

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN 61000-4-2: 95

 

 

 

 

Radiated RF immunity

80 to 2,000 MHz, 10 V/m,

A

EN 61000-4-3: 96

 

 

80% AM with 1 kHz sine

 

 

 

 

900 MHz, 3 V/m, 50% pulse modulation @ 200

 

ENV 50204: 95

 

 

Hz

 

 

 

 

 

 

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

 

 

 

 

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

 

 

 

 

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1

A

EN 61000-4-6: 97

 

 

kHz sine

 

 

 

 

 

 

Power Frequency H-field

1 A/m, 50Hz/60Hz, 3 axes

A

EN 61000-4-8: 97

immunity

 

 

 

 

 

 

 

 

Voltage dips, interrupts

30% Reduction for 25 cycles

C

EN 61000-4-11: 94

 

 

>95% Reduction for 250 cycles

C

 

 

 

>95%, 0.5 cycles

B

 

 

 

 

 

 

A - 1) No upset or degradation in performance beyond manufacturer’s specified limits.

2) No data loss.

B - 1) Unit self recovers without user intervention.

2) No data loss.

C - 1) Upset OK provided that unit will function after user intervention.

14

Momentus 4200.2 Product Manual, Rev. C

Image 20
Contents Momentus Page Contents Momentus 4200.2 Product Manual, Rev. C List of Figures Momentus 4200.2 Product Manual, Rev. C Introduction Momentus 4200.2 Pata disc driveMomentus 4200.2 Product Manual, Rev. C Drive specifications Specification summarySpecifications for 120, 100, and 80 GB models Drive specification ST9120824A ST9100825A ST980829AFollowing web Warranty Specifications for 60, 50, 40, and 30 GB models Drive specification ST960812A ST950814A ST9402112A ST930218ASpecifications for 60, 50, 40, and 30 GB models Default logical geometry LBA modeFormatted capacity Physical organizationPhysical characteristics Technology SpecificationRecording and interface technology Seek timePower specifications Time to readyVoltage tolerance Typical current profileConducted noise Power-management modes Power management modesActive mode Idle modeEnvironmental specifications Shock Operating shockNonoperating shock VibrationAcoustics Electromagnetic immunityDrive level acoustics Electromagnetic immunitySafety certification Measurement type SpecificationReliability Agency certificationFCC verification Korean RRLAustralian C-Tick N176 European Union Restriction of Hazardous Substances RoHS Environmental protectionCorrosive environment Momentus 4200.2 Product Manual, Rev. C Configuring and mounting the drive Handling and static discharge precautionsCable-select option Jumper settingsMaster/slave configuration Mounting dimensions-top, side and end view Drive mountingMomentus 4200.2 Product Manual, Rev. C ATA interface signals and connector pins Connector signalsConnector Cable Signal Name Contact Conductor Cable Connector Conductor Contact Signal NameCommand name Command code in hex ATA-standard commands Supported ATA commandsSupported commands ATA-standard security commands Command name Command code in hexATA-standard power-management commands Identify Device command Word Description ValueXxxxH Description if bit is set to Bit Word Bit WordSet Features command Features register valuesMomentus 4200.2 Product Manual, Rev. C Installation considerations Compatibility summarySystem Compatibility Tested systemsVendor Release Revision Bios versions testedTested Bios versions Compatibility test configurations Operating system versions testedSoftware utilities Other certificationSeagate Technology support services InternetPresales Support Technical SupportData Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Index Page Page Momentus 4200.2 Product Manual, Rev. C Page Seagate Technology LLC