Word | Description | Value |
|
|
|
|
|
59 | Number of sectors transferred during a Read Multiple or | xxxxH |
|
| Write Multiple command |
|
|
Total number of | ST95005620AS | = 0FFFFFFFh | |
| This field contains a value that is one greater than the total | ST93205620AS | = 0FFFFFFFh |
| number of | ST92505610AS | = 0FFFFFFFh |
| that shall be placed in this field is 0FFFFFFFh. The |
|
|
| 0FFFFFFFh value applies to all capacities over 137GB |
|
|
| (see Section 2.2 and 2.3 for related information). |
|
|
|
|
|
|
62 | Retired | 0000H |
|
63 | Multiword DMA active and modes supported | xx07H |
|
| (see note following this table) |
|
|
64 | Advanced PIO modes supported (modes 3 and 4 supported) | 0003H |
|
65 | Minimum multiword DMA transfer cycle time per word | 0078H |
|
| (120 ns) |
|
|
66 | Recommended multiword DMA transfer cycle time per word | 0078H |
|
| (120 ns) |
|
|
67 | Minimum PIO cycle time without IORDY flow control (240 ns) | 00F0H |
|
68 | Minimum PIO cycle time with IORDY flow control (120 ns) | 0078H |
|
0000H |
| ||
75 | Queue depth | 0000H |
|
76 | Serial ATA capabilities | 0508H |
|
77 | 0000H |
| |
78 | Serial ATA features supported | 0048H |
|
79 | Serial ATA features enabled | 0040H |
|
80 | Major version number | 003EH |
|
81 | Minor version number | 0000H |
|
82 | Command sets supported | 306BH |
|
83 | Command sets supported | 4001H |
|
84 | Command sets support extension | 4000H |
|
85 | Command sets enabled | 30xxH |
|
86 | Command sets enabled | 0001H |
|
87 | Command sets enable extension | 4000H |
|
88 | Ultra DMA support and current mode | xx7FH |
|
| (see note following this table) |
|
|
89 | Security erase time | 0000H |
|
90 | Enhanced security erase time | 0000H |
|
92 | Master password revision code | FFFEH |
|
93 | Hardware reset value (see description following this table) | xxxxH |
|
94 | Auto acoustic management setting | xxxxH |
|
0000H |
|
Momentus XT Product Manual, Rev. B | 27 |