2.7Seek time
Seek measurements are taken with nominal power at 25°C ambient temperature. All times are measured using drive diagnostics. The specifications in the table below are defined as follows:
•
•Average seek time is a true statistical random average of at least 5000 measurements of seeks between random tracks, less overhead.
Table 2: Typical seek times
Typical seek times (ms) | Read |
|
|
1.5 | |
|
|
Average | 11.0 |
|
|
22.0 | |
|
|
Average latency | 4.17 |
|
|
Note. These drives are designed to consistently meet the seek times represented in this manual. Physical seeks, regardless of mode (such as
2.8Start/stop times
Time to ready | Typical | Max @ 25°C |
|
|
|
4.5 | 5.0 | |
|
|
|
Standby to Ready (sec) | 3.0 | 3.5 |
|
|
|
Momentus XT Product Manual, Rev. A | 7 |