Seagate ST31000340AS, ST31000640AS, ST3750330AS, ST3750630AS, ST3500820AS, ST3500620AS manual Xx07H

Page 35

Word

Description

Value

 

 

 

 

 

 

Total number of user-addressable LBA sectors available

 

 

 

(see Section 2.1 for related information)

 

 

60–61

*Note: The maximum value allowed in this field is: 0FFFFFFFh

0FFFFFFFh*

 

(268,435,455 sectors, 137 Gbytes). Drives with capacities over 137

 

 

Gbytes will have 0FFFFFFFh in this field and the actual number of

 

 

 

user-addressable LBAs specified in words 100-103. This is required

 

 

 

for drives that support the 48-bit addressing feature.

 

 

 

 

 

 

62

Retired

0000H

 

63

Multiword DMA active and modes supported (see note following this

xx07H

 

table)

 

 

 

 

 

64

Advanced PIO modes supported (modes 3 and 4 supported)

0003H

 

65

Minimum multiword DMA transfer cycle time per word (120 nsec)

0078H

 

66

Recommended multiword DMA transfer cycle time per word (120

0078H

 

nsec)

 

 

 

 

 

67

Minimum PIO cycle time without IORDY flow control (240 nsec)

00F0H

 

68

Minimum PIO cycle time with IORDY flow control (120 nsec)

0078H

 

69–74

ATA-reserved

0000H

 

75

Queue depth

0000H

 

76

Serial ATA capabilities

xxxxH

 

77

Reserved for future Serial ATA definition

xxxxH

 

78

Serial ATA features supported

xxxxH

 

79

Serial ATA features enabled

xxxxH

 

80

Major version number

003EH

 

81

Minor version number

0000H

 

82

Command sets supported

364BH

 

83

Command sets supported

7C03H

 

84

Command sets support extension

4003H

 

85

Command sets enabled

30xxH

 

86

Command sets enabled

0001H

 

87

Command sets enable extension

4000H

 

88

Ultra DMA support and current mode (see note following this table)

xx3FH

 

89

Security erase time

0000H

 

90

Enhanced security erase time

0000H

 

92

Master password revision code

FFFEH

 

93

Hardware reset value (see description following this table)

xxxxH

 

95–99

ATA-reserved

0000H

 

 

 

ST31000340AS =1,953,525,168

 

Total number of user-addressable LBA sectors available (see Section

ST31000640AS =1,953,525,168

 

ST3750330AS = 1,465,149,168

 

2.1 for related information). These words are required for drives that

100–103

ST3750630AS = 1,465,149,168

support the 48-bit addressing feature. Maximum value:

 

ST3500320AS =

976,773,168

 

0000FFFFFFFFFFFFh.

 

ST3500620AS =

976,773,168

 

 

 

 

ST3500820AS =

976,773,168

 

 

 

 

104–127

ATA-reserved

0000H

 

Barracuda 7200.11 Serial ATA Product Manual, Rev. C

29

Image 35
Contents Barracuda 7200.11 Serial ATA Revision Date Sheets affected or comments Revision historyContents Barracuda 7200.11 Serial ATA Product Manual, Rev. C Typical 5V startup and operation current profile List of FiguresPage Introduction About the Serial ATA interface Drive specifications Drive specifications summary for 1000 and 750 Gbyte models Barracuda 7200.11 Serial ATA Product Manual, Rev. C Drive specifications summary for 500 Gbyte models Barracuda 7200.11 Serial ATA Product Manual, Rev. C Recording and interface technology Default logical geometryLBA mode Formatted capacityTypical seek times msec Read Write Physical characteristicsSeek time Start/stop timesPower specifications Typical 12V startup and operation current profile Typical 5V startup and operation current profileSleep mode Power-management modesActive mode Idle modeEnvironmental specifications 1000 GB, 750 GB and 500 GB models VibrationOperating vibration Nonoperating vibrationTest for Prominent Discrete Tones PDTs AcousticsElectromagnetic immunity Fluid Dynamic Bearing FDB motor acousticsElectromagnetic compatibility Safety certificationReliability Agency certificationFCC verification Korean RRLAustralian C-Tick N176 Corrosive environment超出 Environmental protectionHandling and static-discharge precautions Configuring and mounting the driveSerial ATA cables and connectors Configuring the driveDrive mounting Mounting dimensionsBarracuda 7200.11 Serial ATA Product Manual, Rev. C Hot-Plug compatibility Serial ATA Sata interfacePin Function Definition Serial ATA device plug connector pin definitionsSerial ATA connector pin definitions SignalCommand name Command code in hex Supported ATA commandsSupported ATA commands F3H Command name Command code in hex Write Sectors Extended 34H Word Description Value Identify Device commandXx07H Bit Word Description if bit is set to Bit WordSet Features command values Set Features commandCode in features register A.R.T. command 3 S.M.A.R.T. commandsA.R.T. commands Technical Support Seagate Technology support servicesInternet Presales SupportData Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Index Page Sata Barracuda 7200.11 Serial ATA Product Manual, Rev. C Page Seagate Technology LLC
Related manuals