Seagate ST3300655LC manual Thermal monitor, Temperature Log page 0Dh Parameter Code Description

Page 24

zero) whenever the error rate is acceptable. This counter is referred to as the Failure History Counter. There is a separate Failure History Counter for each attribute. Should the counter continually be incremented such that it reaches the predictive threshold, a predictive failure is signaled.

6.2.5Thermal monitor

Cheetah 15K.5 SCSI drives implement a temperature warning system which:

1.Signals the host if the temperature exceeds a value which would threaten the drive.

2.Signals the host if the temperature exceeds a user-specified value.

3.Saves a S.M.A.R.T. data frame on the drive which exceed the threatening temperature value.

A temperature sensor monitors the drive temperature and issues a warning over the interface when the tem- perature exceeds a set threshold. The temperature is measured at power-up and then at ten-minute intervals after power-up.

The thermal monitor system generates a warning code of 01-0B01 when the temperature exceeds the speci- fied limit in compliance with the SCSI standard. The drive temperature is reported in the FRU code field of mode sense data. You can use this information to determine if the warning is due to the temperature exceeding the drive threatening temperature or the user-specified temperature.

This feature is controlled by the Enable Warning (EWasc) bit, and the reporting mechanism is controlled by the Method of Reporting Informational Exceptions field (MRIE) on the Informational Exceptions Control (IEC) mode page (1Ch).

The current algorithm implements two temperature trip points. The first trip point is set at 68°C which is the maximum temperature limit according to the drive specification. The second trip point is user-selectable using the Log Select command. The reference temperature parameter in the temperature log page (see Table 2) can be used to set this trip point. The default value for this drive is 68°C, however, you can set it to any value in the range of 0 to 68°C. If you specify a temperature greater than 68°C in this field, the temperature is rounded down to 68°C. A sense code is sent to the host to indicate the rounding of the parameter field.

Table 2: Temperature Log page (0Dh)

Parameter Code

Description

 

 

0000h

Primary Temperature

 

 

0001h

Reference Temperature

 

 

When the first temperature trip point is exceeded, S.M.A.R.T. data is collected and a frame is saved to the disc.

6.2.6Drive Self Test (DST)

Drive Self Test (DST) is a technology designed to recognize drive fault conditions that qualify the drive as a failed unit. DST validates the functionality of the drive at a system level.

There are two test coverage options implemented in DST:

1.Extended test

2.Short text

The most thorough option is the extended test that performs various tests on the drive and scans every logical block address (LBA) of the drive. The short test is time-restricted and limited in length—it does not scan the entire media surface, but does some fundamental tests and scans portions of the media.

If DST encounters an error during either of these tests, it reports a fault condition. If the drive fails the test, remove it from service and return it to Seagate for service.

18

Cheetah 15K.5 SCSI Product Manual, Rev. J

Image 24
Contents Cheetah 15K.5 Scsi Page Contents Defect and error management InstallationInterface requirements List of Figures Page Seagate Technology support services Seagate Online Support and ServicesScope Applicable standards and reference documentation StandardsElectromagnetic compatibility Electromagnetic susceptibilityElectromagnetic compliance European Union Restriction of Hazardous Substances RoHSReference documents Drive model number vs. differentiating features General descriptionStandard features Media characteristicsPerformance ReliabilityFormatted capacities Factory installed accessories Options factory installedAccessories Programmable drive capacityPerformance characteristics Internal drive characteristics transparent to userScsi performance characteristics visible to user Format command execution time minutes Generalized performance characteristicsSeek time Start/stop time Prefetch/multi-segmented cache controlCache operation Caching write data Prefetch operationReliability specifications Error ratesRecoverable Errors Unrecoverable ErrorReliability and service Seek errorsPreventive maintenance Hot plugging Cheetah 15K.5 Scsi disc drives 4 S.M.A.R.TControlling S.M.A.R.T Performance impactMilliseconds Reporting controlTemperature Log page 0Dh Parameter Code Description Thermal monitorDrive Self Test DST State of the drive prior to testing DST Failure DefinitionImplementation Invoking DSTProduct warranty Short test Function Code 001bExtended test Function Code 010b Log page entriesShipping Product repair and return informationPhysical/electrical specifications AC power requirementsDC power requirements ST3300655LC DC power requirementsST3146855LC DC power requirements ST373455LC DC power requirementsPower sequencing Conducted noise immunityCurrent profile Typical ST3300655LW drive +12V LVD current profile Power dissipation ST3300655LW/ST3300655LCST3146855LC DC current and power vs. Iops LVD ST3146855LW/ST3146855LCST373455LC DC current and power vs. Iops LVD ST373455LW/ST373455LCTemperature a. Operating Environmental limitsRelative humidity Effective altitude sea level a. OperatingShock and vibration ShockRecommended mounting Air cleanliness Vibration a. Operating-normalCorrosive environment Mechanical specifications AcousticsLC mounting configuration dimensions Defect and error management Drive error recovery proceduresDrive internal defects Read and write retry count maximum recovery times Scsi systems errors Background Media ScanMedia Pre-Scan Deferred Auto-Reallocation Idle Read After WriteInstallation Configure drive optionsDrive ID/option select header FormattingJ5 jumper header on LW models only Drive Front Function description RESDrive orientation CoolingDrive mounting GroundingInterface requirements General descriptionScsi interface messages supported Scsi messages supported by Cheetah 15K.5 Scsi family drivesScsi interface commands supported Commands supported by Cheetah 15K.5 Scsi family driveCommands supported by Cheetah 15K.5 Scsi family drive Commands supported by Cheetah 15K.5 Scsi family drive Commands supported by Cheetah 15K.5 Scsi family drive Cheetah 15K.5 Scsi family drive Standard Inquiry data Inquiry Vital Product dataMode Sense data ST3300655 Mode sense data Mode Sense Pages DataST3146855 Mode sense data Mode Sense Header Data Mode Sense Pages DataST373455 Mode sense data Scsi bus conditions and miscellaneous features supported Scsi bus conditions and other miscellaneous featuresSynchronous data transfer Physical interfaceDC cable and connector Scsi interface physical description Mating connectors Interface transfer rates supportedScsi interface cable requirements Cable requirementsMating connectors for LW model drives Mating connectors for LC model drivesRight-angle to Pcba connectors Scsi daisy-chain interface cabling for LW drivesNonshielded 68-pin Scsi device connector used on LW drives Nonshielded 80-pin Scsi SCA-2 connector used on LC drives GND LW 68-conductor LVD P cable signal/pin assignments LC 80-pin single-ended SE I/O connector pin assignments Active LED OUT 4LC 80-pin single-ended LVD I/O connector pin assignments +5 V Charge GND Active LED OUT 4LVD output characteristics Electrical descriptionMultimode-SE and LVD alternatives LVD Input characteristics General cable characteristicsCable characteristics for single-ended circuits Single-ended drivers/receiversCables for low voltage differential drivers/receivers Twist-n-flat cables-into a multi-drive backplaneTerminator requirements Terminator power LW drivesLC drives Disc drive Scsi timing Disc drive Scsi timingDisc drive Scsi timing Drive activity LED status Spindle status Command status Drive activity LEDSymbols NumericsPage Page Scsi Page Page