Seagate ST3450657SS Reporting control, Determining rate, Predictive failures, Thermal monitor

Page 22

Reporting control

Reporting is controlled by the MRIE bits in the Informational Exceptions Control mode page (1Ch). Subject to the reporting method, the firmware will issue to the host an 01-5Dxx sense code. The error code is preserved through bus resets and power cycles.

Determining rate

S.M.A.R.T. monitors the rate at which errors occur and signals a predictive failure if the rate of degraded errors increases to an unacceptable level. To determine rate, error events are logged and compared to the number of total operations for a given attribute. The interval defines the number of operations over which to measure the rate. The counter that keeps track of the current number of operations is referred to as the Interval Counter.

S.M.A.R.T. measures error rates. All errors for each monitored attribute are recorded. A counter keeps track of the number of errors for the current interval. This counter is referred to as the Failure Counter.

Error rate is the number of errors per operation. The algorithm that S.M.A.R.T. uses to record rates of error is to set thresholds for the number of errors and their interval. If the number of errors exceeds the threshold before the interval expires, the error rate is considered to be unacceptable. If the number of errors does not exceed the threshold before the interval expires, the error rate is considered to be acceptable. In either case, the inter- val and failure counters are reset and the process starts over.

Predictive failures

S.M.A.R.T. signals predictive failures when the drive is performing unacceptably for a period of time. The firm- ware keeps a running count of the number of times the error rate for each attribute is unacceptable. To accom- plish this, a counter is incremented each time the error rate is unacceptable and decremented (not to exceed zero) whenever the error rate is acceptable. If the counter continually increments such that it reaches the pre- dictive threshold, a predictive failure is signaled. This counter is referred to as the Failure History Counter. There is a separate Failure History Counter for each attribute.

6.2.5Thermal monitor

Cheetah 15K.7 drives implement a temperature warning system which:

1.Signals the host if the temperature exceeds a value which would threaten the drive.

2.Signals the host if the temperature exceeds a user-specified value.

3.Saves a S.M.A.R.T. data frame on the drive which exceeds the threatening temperature value.

A temperature sensor monitors the drive temperature and issues a warning over the interface when the tem- perature exceeds a set threshold. The temperature is measured at power-up and then at ten-minute intervals after power-up.

The thermal monitor system generates a warning code of 01-0B01 when the temperature exceeds the speci- fied limit in compliance with the SCSI standard. The drive temperature is reported in the FRU code field of mode sense data. You can use this information to determine if the warning is due to the temperature exceeding the drive threatening temperature or the user-specified temperature.

This feature is controlled by the Enable Warning (EWasc) bit, and the reporting mechanism is controlled by the Method of Reporting Informational Exceptions field (MRIE) on the Informational Exceptions Control (IEC) mode page (1Ch).

The current algorithm implements two temperature trip points. The first trip point is set at 68°C which is the maximum temperature limit according to the drive specification. The second trip point is user-selectable using the Log Select command. The reference temperature parameter in the temperature log page (see Table 13)

16

Cheetah 15K.7 SAS Product Manual, Rev. D

Image 22
Contents ST3300457SS ST3600857SSST3450657SS Standard models Self-Encrypting Drive modelsPage Contents About Fips About self-encrypting drives Defect and error managementInstallation Interface requirementsPower Cheetah 15K.7 SAS Product Manual, Rev. D Seagate Technology support services Seagate Online Support and ServicesScope Electromagnetic compatibility Standards, compliance and reference documentsStandards Electromagnetic susceptibilityCompliance European Union Restriction of Hazardous Substances RoHSReference documents General description Media description Standard featuresPerformance Formatted capacities Factory-installed optionsReliability Programmable drive capacityAccess time Performance characteristicsInternal drive characteristics Seek timeGeneral performance characteristics Format command execution time minutesStart/stop time Prefetch/multi-segmented cache control Cache operationCaching write data Prefetch operationRecoverable Errors Reliability specificationsError rates Unrecoverable ErrorsInterface errors Reliability and serviceSeek errors Preventive maintenancePerformance impact 4 S.M.A.R.TControlling S.M.A.R.T MillisecondsPredictive failures Reporting controlDetermining rate Thermal monitorDrive Self Test DST Temperature Log Page 0Dh Parameter Code DescriptionState of the drive prior to testing DST failure definitionShort test Function Code 001b Invoking DSTShort and extended tests Extended test Function Code 010bShipping Product warrantyAbort Product repair and return informationAC power requirements Physical/electrical specificationsDC power requirements 600 GB DC power requirements Gbit mode Amps450 GB DC power requirements 300 GB DC power requirements Conducted noise immunity Power sequencingCurrent profiles Typical 600GB current profiles Typical 300GB current profiles Power dissipation 450GB model Temperature a. Operating Environmental limitsShock and vibration Relative humidityEffective altitude sea level a. Operating ShockPackage size Packaged/product weight Drop height Vibration a. Operating-normal Recommended mountingCorrosive environment Air cleanlinessAcoustics RoHS compliance statementMechanical specifications Units of Measure mm inchesPurpose About FipsLevel 2 security About self-encrypting drives Controlled accessAdmin SP Data encryptionDrive locking Authenticated firmware downloadRandom number generator RNG Data bandsPower requirements Supported commandsDrive internal defects/errors Defect and error managementDrive error recovery procedures Page SAS system errors Background Media ScanDeferred Auto-Reallocation Media Pre-ScanIdle Read After Write Drive orientation InstallationCooling Drive mounting GroundingSAS features Interface requirementsCommands supported by Cheetah 15K.6 SAS family drives Scsi commands supportedDual port support Commands supported by Cheetah 15K.6 SAS family drives Commands supported by Cheetah 15K.6 SAS family drives Commands supported by Cheetah 15K.6 SAS family drives Inquiry data Cheetah 15K.7 inquiry data Bytes Data hexMode Sense data 12.3.2.1 600GBmodel Mode Sense data Mode PagesDEF CHG 12.3.2.2 450GB model Mode Sense data Mode Data Header Block Descriptor Mode PagesDEF CHG Read Capacity Data Buffer C D E F 12.3.2.3 300GB model Mode Sense data Mode PagesMiscellaneous operating features and conditions Miscellaneous featuresMiscellaneous status SAS physical interfaceDatum B Physical characteristics Connector requirementsPin descriptions Electrical descriptionSAS pin descriptions SAS transmitters and receivers Signal characteristicsPower Ready LED OutDifferential signals SAS-2 Specification complianceLED drive signal General interface characteristicsCheetah 15K.7 SAS Product Manual, Rev. D Index NumericsPage SAS Smart