[6]Operating condition is defined as random 8 block reads at 375 I/Os per second for 600GB models, and 380 I/Os per second for 450GB and 300GB models. Current and power specified at nominal voltages.
[7]During idle, the drive heads are relocated every 60 seconds to a random location within the band from
General DC power requirement notes.
1.Minimum current loading for each supply voltage is not less than 1.7% of the maximum operating current shown.
2.The +5V and +12V supplies should employ separate ground returns.
3.Where power is provided to multiple drives from a common supply, careful consideration for individual drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak starting current must be available to each device.
4.Parameters, other than spindle start, are measured after a
5.No terminator power.
7.2.1Conducted noise immunity
Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz. Maximum allowed noise values given below are
+5V | = | 250 mV pp from 0 to 100 kHz to 20 MHz. |
+12V | = | 800 mV pp from 100 Hz to 8 KHz. |
|
| 450 mV pp from 8 KHz to 20 KHz. |
|
| 250 mV pp from 20 KHz to 5 MHz. |
7.2.2Power sequencing
The drive does not require power sequencing. The drive protects against inadvertent writing during
7.2.3Current profiles
The +12V and +5V current profiles are shown below in the following figures.
Note: All times and currents are typical. See Tables 14, 15, and 16 for maximum current requirements.
24 | Cheetah 15K.7 SAS Product Manual, Rev. D |