Seagate ST3450657SS Random number generator RNG, Drive locking, Data bands, Cryptographic erase

Page 43

9.2.3Default password

When the drive is shipped from the factory, all passwords are set to the value of MSID. This 32-byte random value is printed on the drive label and it can be read by the host electronically over the I/O. After receipt of the drive, it is the responsibility of the owner to use the default MSID password as the authority to change all other passwords to unique owner-specified values.

9.3Random number generator (RNG)

The drive has a 32-byte hardware RNG that it is uses to derive encryption keys or, if requested to do so, to pro- vide random numbers to the host for system use, including using these numbers as Authentication Keys (pass- words) for the drive’s Admin and Locking SPs.

9.4Drive locking

In addition to changing the passwords, as described in Section 9.2.3, the owner should also set the data access controls for the individual bands.

The variable "LockOnReset" should be set to "PowerCycle" to ensure that the data bands will be locked if power is lost. This scenario occurs if the drive is removed from its cabinet. The drive will not honor any data read or write requests until the bands have been unlocked. This prevents the user data from being accessed without the appropriate credentials when the drive has been removed from its cabinet and installed in another system.

When the drive is shipped from the factory, the firmware download port is locked and the drive will reject any attempt to download new firmware. The drive owner must use the SID credential to unlock the firmware down- load port before firmware updates will be accepted.

9.5Data bands

When shipped from the factory, the drive is configured with a single data band called Band 0 (also known as the Global Data Band) which comprises LBA 0 through LBA max. The host may allocate Band1 by specifying a start LBA and an LBA range. The real estate for this band is taken from the Global Band. An additional 14 Data Bands may be defined in a similar way (Band2 through Band15) but before these bands can be allocated LBA space, they must first be individually enabled using the EraseMaster password.

Data bands cannot overlap but they can be sequential with one band ending at LBA (x) and the next beginning at LBA (x+1).

Each data band has its own drive-generated encryption key and its own user-supplied password. The host may change the Encryption Key (see Section 9.6) or the password when required. The bands should be aligned to 4K LBA boundaries.

9.6Cryptographic erase

A significant feature of SEDs is the ability to perform a cryptographic erase. This involves the host telling the drive to change the data encryption key for a particular band. Once changed, the data is no longer recoverable since it was written with one key and will be read using a different key. Since the drive overwrites the old key with the new one, and keeps no history of key changes, the user data can never be recovered. This is tanta- mount to an instantaneous data erase and is very useful if the drive is to be scrapped or redispositioned.

9.7Authenticated firmware download

In addition to providing a locking mechanism to prevent unwanted firmware download attempts, the drive also only accepts download files which have been cryptographically signed by the appropriate Seagate Design Center.

Three conditions must be met before the drive will allow the download operation:

1. The download must be an SED file. A standard (base) drive (non-SED) file will be rejected.

Cheetah 15K.7 SAS Product Manual, Rev. D

37

Image 43
Contents Standard models Self-Encrypting Drive models ST3600857SSST3450657SS ST3300457SSPage Contents Interface requirements Defect and error managementInstallation About Fips About self-encrypting drivesPower Cheetah 15K.7 SAS Product Manual, Rev. D Seagate Online Support and Services Seagate Technology support servicesScope Electromagnetic susceptibility Standards, compliance and reference documentsStandards Electromagnetic compatibilityEuropean Union Restriction of Hazardous Substances RoHS ComplianceReference documents General description Media description Standard featuresPerformance Programmable drive capacity Factory-installed optionsReliability Formatted capacitiesSeek time Performance characteristicsInternal drive characteristics Access timeGeneral performance characteristics Format command execution time minutesStart/stop time Cache operation Prefetch/multi-segmented cache controlPrefetch operation Caching write dataUnrecoverable Errors Reliability specificationsError rates Recoverable ErrorsPreventive maintenance Reliability and serviceSeek errors Interface errorsMilliseconds 4 S.M.A.R.TControlling S.M.A.R.T Performance impactThermal monitor Reporting controlDetermining rate Predictive failuresDST failure definition Temperature Log Page 0Dh Parameter Code DescriptionState of the drive prior to testing Drive Self Test DSTExtended test Function Code 010b Invoking DSTShort and extended tests Short test Function Code 001bProduct repair and return information Product warrantyAbort ShippingAC power requirements Physical/electrical specificationsDC power requirements Gbit mode Amps 600 GB DC power requirements450 GB DC power requirements 300 GB DC power requirements Conducted noise immunity Power sequencingCurrent profiles Typical 600GB current profiles Typical 300GB current profiles Power dissipation 450GB model Environmental limits Temperature a. OperatingShock Relative humidityEffective altitude sea level a. Operating Shock and vibrationPackage size Packaged/product weight Drop height Recommended mounting Vibration a. Operating-normalRoHS compliance statement Air cleanlinessAcoustics Corrosive environmentUnits of Measure mm inches Mechanical specificationsPurpose About FipsLevel 2 security Data encryption Controlled accessAdmin SP About self-encrypting drivesData bands Authenticated firmware downloadRandom number generator RNG Drive lockingSupported commands Power requirementsDrive internal defects/errors Defect and error managementDrive error recovery procedures Page Background Media Scan SAS system errorsDeferred Auto-Reallocation Media Pre-ScanIdle Read After Write Drive orientation InstallationCooling Grounding Drive mountingInterface requirements SAS featuresCommands supported by Cheetah 15K.6 SAS family drives Scsi commands supportedDual port support Commands supported by Cheetah 15K.6 SAS family drives Commands supported by Cheetah 15K.6 SAS family drives Commands supported by Cheetah 15K.6 SAS family drives Cheetah 15K.7 inquiry data Bytes Data hex Inquiry dataMode Sense data Mode Pages 12.3.2.1 600GBmodel Mode Sense dataDEF CHG Mode Data Header Block Descriptor Mode Pages 12.3.2.2 450GB model Mode Sense dataDEF CHG Read Capacity Data Buffer C D E F Mode Pages 12.3.2.3 300GB model Mode Sense dataMiscellaneous features Miscellaneous operating features and conditionsSAS physical interface Miscellaneous statusDatum B Connector requirements Physical characteristicsPin descriptions Electrical descriptionSAS pin descriptions Ready LED Out Signal characteristicsPower SAS transmitters and receiversGeneral interface characteristics SAS-2 Specification complianceLED drive signal Differential signalsCheetah 15K.7 SAS Product Manual, Rev. D Numerics IndexPage SAS Smart