Table 1: | Specifications |
|
| |
|
|
| ||
Drive specification | ST760211DE | ST730212DE | ||
|
|
| ||
Temperature gradient (°C per hour max) | 20°C (operating) |
| ||
|
| 30°C (nonoperating) |
| |
|
|
| ||
Relative humidity (noncondensing) | 5% to 90% (operating) |
| ||
|
| 5% to 95% (nonoperating) |
| |
Relative humidity gradient | 30% per hour max |
| ||
|
|
| ||
Wet bulb temperature (°C max) | 33°C (operating) |
| ||
|
| 40°C (nonoperating) |
| |
|
| |||
Altitude, operating | ||||
|
| |||
Altitude, nonoperating (below mean sea level, max) | ||||
|
|
| ||
Shock, operating (Gs max at 2 msec) | 500 |
| ||
|
|
| ||
Shock, nonoperating (Gs max at 1 msec) | 1500 |
| ||
|
|
| ||
Vibration, operating | 1.0 Gs (0 to peak, | |||
(max displacement may apply below 10 hz) | ||||
|
| |||
|
|
| ||
Vibration, nonoperating | 5.0 Gs (0 to peak, | |||
(max displacement may apply below 22 hz) | ||||
|
| |||
|
|
| ||
Idle sound power (bels) (typical) | 1.6 |
| ||
|
|
| ||
Operational sound power (bels) (typical) | 2.2 |
| ||
|
|
| ||
Nonrecoverable read errors | 1 per 1014 bits read |
| ||
Load/Unload (LUL) cycles | 20,000 power loss |
| ||
|
|
|
|
2.2Formatted capacity
Model | Formatted | Guaranteed | Bytes per |
| capacity | sectors | sector (logical) |
|
|
|
|
ST760211DE | 60 Gbytes | 117,210,240 | 512 |
|
|
|
|
ST730212DE | 30 Gbytes | 58,605,120 | 512 |
|
|
|
|
LBA mode addressing
When addressing these drives in LBA mode, all blocks (sectors) are consecutively numbered from 0 to
2.3Default logical geometry
Model | Cylinders | Heads | Sectors |
|
|
|
|
ST760211DE | 116,280 | 16 | 63 |
|
|
|
|
ST730212DE | 58,149 | 16 | 63 |
|
|
|
|
4 | Lyrion Series IDE Product Manual, Rev. B |