White Rodgers 1F82-261 Manual Operation, Programming Your Thermostat, Planning Your Program

Page 6

4)Select backlit display - The display backlight improves display contrast in low lighting conditions. Selecting back- light ON will keep the light on continuously. Selecting OFF will keep the light off.

5)Select Energy Management Recovery OFF or ON - Energy Management Recovery (EMR) causes the thermo- stat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify.

6)Select filter replacement run time - The thermostat will display FLTR after a set time of operation. This is a reminder to change or clean your air filter. This time can be set from 0 to 1950 hours in 50 hour increments. A selection of 000 will cancel this feature. When FLTR is displayed, you can clear it by pressing HOLD and RUN at the same time. This resets the timer and starts counting the hours until the next filter change. Contact your heat pump manu- facturer for a specific replacement/maintenance interval.

7)Select Compressor Lockout LOC OFF or ON - Selecting LOC ON will cause the thermostat to wait 5 minutes before turning on the compressor if the heating and cooling system loses power. It will also wait 5 minutes minimum between cooling or heating cycles. This is intended to help protect the compressor from short cycling. Some newer compres- sors already have a time delay built in and do not require this feature. Your compressor manufacturer can tell you if the lockout feature is already present in their system. When the thermostat compressor time delay occurs it will flash the Snowflake and Flame icons for about five minutes.

8)Select Temperature Display Adjustment 4 LO to 4 HI - Allows you to adjust the room temperature display up to 4° higher or lower. Your thermostat was accurately calibrated at the factory but you have the option to change the display temperature to match your previous thermostat. The cur- rent or adjusted room temperature will be displayed on the right side of the display.

9)Select F° or C° Readout - Changes the display readout to Celsius or Fahrenheit as required. The current room tem- perature will be displayed on the right side of the display.

10)Select Fast second stage - In the RUN mode, if the temperature is manually raised by 3°F ( 2°C) or more above

room temperature using and the fast second stage feature is enabled, FA on, the second stage will energige immediately. With FA off, the second stage will not energize until the setpoint temperature is 10°F or more above room temperature.

SAMPLE

Heating/Cooling Schedule Plan (Factory Program)

 

 

WEEKDAYS

SATURDAY

SUNDAY

 

 

(5 Day)

(1 Day)

(1 Day)

Period

Start

 

Start

 

Start

 

Time

Temp

Time

Temp

Time

Temp

 

 

 

1ST

6:00 AM

70° F

6:00 AM

70° F

6:00 AM

70° F

 

 

 

 

 

 

 

 

HEAT

2ND

8:00 AM

62° F

8:00 AM

62° F

8:00 AM

62° F

 

 

 

 

 

 

 

3RD

5:00 PM

70° F

5:00 PM

70° F

5:00 PM

70° F

 

 

 

 

 

 

 

 

 

 

4TH

10:00 PM

62° F

10:00 PM

62° F

10:00 PM

62° F

 

 

 

 

 

 

 

 

 

1ST

6:00 AM

78° F

6:00 AM

78° F

6:00 AM

78° F

COOL

 

 

 

 

 

 

 

2ND

8:00 AM

85° F

8:00 AM

85° F

8:00 AM

85° F

 

 

 

 

 

 

 

3RD

5:00 PM

78° F

5:00 PM

78° F

5:00 PM

78° F

 

 

 

 

 

 

 

 

 

 

4TH

10:00 PM

82° F

10:00 PM

82° F

10:00 PM

82° F

 

 

 

 

 

 

 

 

MANUAL OPERATION

HOLD TEMPERATURE — With the SYSTEM switch set to HEAT or COOL, momentarily press HOLD button. HOLD

will be displayed. Use or to adjust the temperature. The thermostat will hold the room temperature at the selected setting until you press RUN button to start program operation again.

TEMPERATURE OVERRIDE — Press or until the temperature you want is displayed. The thermostat will override current programming and keep the room tem- perature at the selected temperature until the next program period begins. Then the thermostat will automatically re- vert to the program.

TEMPORARY HOLD TEMPERATURE — The thermostat can hold any temperature within its range for the length of time selected in the configuration menu. See Configuration Menu section, step 1.

PROGRAMMING YOUR THERMOSTAT

This section will help you plan your thermostat’s program to meet your needs. For maximum comfort and efficiency, keep the following guidelines in mind when planning your program.

When heating (cooling) your building, program the tem- peratures to be cooler (warmer) when the building is vacant or during periods of low activity.

During early morning hours, the need for cooling is usually minimal.

Planning Your Program

Look at the factory preprogrammed times and temperatures shown in the sample schedule. If this program will suit your needs, simply press the RUN button to begin running the factory preset program.

If you want to change the preprogrammed times and tempera- tures, follow these steps.

Determine the time periods and temperatures for your program. You must program four periods for each day. However, you may use the same heating and cooling temperatures for consecutive time periods. You can choose start times, heating temperatures, and cooling temperatures independently (for example, you may select 5:00 AM and 70°as the weekday 1st period heating start time and temperature, and also choose 7:00 AM and 76° as the weekday 1st period cooling start time and temperature).

Heating/Cooling Schedule Plan

 

 

WEEKDAYS

SATURDAY

SUNDAY

 

 

(5 Day)

(1 Day)

(1 Day)

Period

Start

 

Start

 

Start

 

Time

Temp

Time

Temp

Time

Temp

 

 

 

1ST

 

 

 

 

 

 

HEAT

 

 

 

 

 

 

 

2ND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4TH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1ST

 

 

 

 

 

 

COOL

 

 

 

 

 

 

 

2ND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4TH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Image 6
Contents Description PrecautionsSpecifications Part no -6175DInstallation Thermostat SystemOperation Check Thermostat OperationThermostat Base Configuration Menu Configuration MenuDisplay Manual Operation Programming Your ThermostatPlanning Your Program Enter Heating Program Entering Your ProgramSet Current Time and Day Enter Cooling ProgramTroubleshooting Symptom Possible Cause Corrective ActionReset Operation
Related manuals
Manual 2 pages 25.09 Kb

1F82-261 specifications

The White Rodgers 1F82-261 is a programmable thermostat designed to optimize home heating and cooling systems for energy efficiency and comfort. This device is renowned for its user-friendly interface and versatile programming features, making it a popular choice among homeowners seeking to enhance their climate control while potentially reducing energy bills.

One of the main features of the 1F82-261 is its 7-day programmable schedule. This allows users to set different temperature preferences for each day of the week, accommodating unique lifestyles and preferences. With the ability to program multiple hold times throughout the day, homeowners can ensure their living spaces are comfortable when they're home while saving energy when they're away.

The thermostat is equipped with an easy-to-read digital display, which provides clear visibility of the current temperature settings and the programmed schedule. The simplicity of the buttons and menu navigation ensures that users can quickly adjust their settings or program the thermostat without confusion, making it accessible for all members of the household.

In terms of technology, the 1F82-261 integrates advanced temperature control algorithms that enhance the accuracy of heating and cooling cycles. This precision helps maintain a consistent indoor climate, improving comfort while minimizing energy wastage. Additionally, it features a battery backup system that preserves settings in the event of a power outage, ensuring continuous operation and preventing interruption to the programmed schedules.

Another key characteristic of the White Rodgers 1F82-261 is its compatibility with a variety of HVAC systems, including conventional heating systems, heat pumps, and multi-stage setups. This versatility enables a wide range of homeowners to benefit from its efficiency features, regardless of their existing heating or cooling infrastructure.

Furthermore, the thermostat possesses an intuitive “Hold” function, allowing users to override their programmed settings temporarily. This is especially useful for unexpected changes in schedule or when hosting guests, providing flexibility without the need to reprogram the entire week’s schedule.

Overall, the White Rodgers 1F82-261 combines advanced technology, user-friendly features, and robust compatibility, making it an excellent choice for those looking to improve their home comfort efficiency while keeping energy costs manageable. With its seamless integration into various HVAC systems, intuitive operation, and customizable scheduling, it stands out as a formidable option in the thermostat market.