UNIMAX Houseware KVM Switch operation manual Enabling Security

Page 24

NTI UNIMUX MULTI-USER KVM SWITCH

Security

Enabling Security

To enable the security feature the administrator must first enter Command Mode. If the Command Mode menu is not already displayed, press <Ctrl> + <`> (accent/tilde key). The OSD menu will automatically appear on the monitor.

To login as the administrator, the user must first logout by pressing <O>, and then <Y> to confirm. A login prompt will appear.

Password and User Name

The factory settings are:

default user name = <root>

default password = <nti>

Note: The username for the administrator cannot be changed from "root”.

Figure 17- User login screen

Note: The <F1> Autologin key (see Figure 19) is only for use by users other than the administrator, and is only displayed and available for use if security is not enabled.

With a valid login, the user will be connected to the first CPU that is powered-ON. To enter Command Mode, press <Ctrl> + <`> (accent/tilde key). The OSD menu will automatically appear on the monitor.

Figure 18- Administrator's main menu

The administrator will activate security (after logging in) by pressing <A>-<S>-<S>-<E> (see page 26).

Once logged-in, follow the instructions on page 20 for setting up users and changing the password. Once the password is setup, if it is lost or forgotten the administrator will have to contact NTI for assistance on clearing the password and set it up again. The administrator can setup each of the users and the limitations of their use of the individual CPUs using the administration menus.

When a standard user powers up the UNIMUX with security enabled, the login screen will appear. Enter the user name and password as set by the administrator. Unless a valid user name and password are entered, the login screen will remain on the monitor. For more on “User Login”, see page 20.

19

Image 24
Contents UNIMUX-nXm-U Typographic Conventions CopyrightTable of Contents RS232 Control CascadingPort information- system structure Introduction DefinitionsCompatibility CPUOrdering Information MaterialsMaterials Supplied Materials Not Supplied, but RequiredFeatures and Functions NTIAdditional Features Mount Switch to a Rack Rack Mounting InstructionsInstallation NTIUSB Mouse USB Keyboard NTI R Connect each CPU using a USBVEXT-xx-MM cable Using the NTI Unimux USB KVM Switch Basic OperationKeypad Control OSD Control OSD Standards of OperationSecurity Option User Access Functions Command ModeInitial startup Up arrow Settings Administrator main menuOSD Settings Find ModeHelp Mode Scan Mode Scan ListBroadcast Mode Sharing ModeNormal Mode F3- Display Information Port information- system structureSecurity Enabling SecurityAdditional OSD Modes Available With Security Enabled User LoginAdministration Menu System Configuration Port ConfigurationUser Configuration Edit User AccountUser Access Control Change Administrator PasswordIdle Timeout OSD Blank TimeoutAlternate Command Hot Key Reset Port names Select Keyboard LanguageSecurity Configuration Security ConfigurationKeyboard Mapping Key EquivalentsMouse Click Equivalents SUN’s 16 Extra KeysSUN USB Keyboard RS232 Control Remote ConnectionWiring Schematic of Matrix-Y-1 cable RS-232 Command Protocol RS-232 Command Protocol Quick ReferenceAutostatus Setup Options SerTest- RS232 Interface Test ProgramMain Options Matrix OperationsRMTEST-RS232 Interface Test Program Main OptionsCascading LimitationsCascaded configuration with single-user masters Cable ConnectionsNTI R Operating Cascaded Switches SUN RAY SupportSafety Statements CablesUSB-AA-5M USB-A+A-5MTroubleshooting SpecificationsWarranty Information IndexRmtest