Pentax ETH-310, ETH-302, ETH-305 Preparation for Surveying, Setting up the instrument

Page 28

4. Preparation for Surveying

4.1 Setting up the instrument

1Adjust the tripod legs so that a height suitable for surveying is obtained when the instrument is set on the tripod.

2A Set the tripod and fix the metal shoe firmly into the ground so that the tripod head is as level as possible and centered above the station point. If the tripod head is disturbed by the action of fixing the metal shoe into the ground, correct the level by extending or retracting each leg of the tripod.

3Set the instrument on the tripod head; insert the tripod center screw into the instrument bottom plate and tighten firmly.

Tripod head

Bottom plate

 

Center screw

Tripod

28

Image 28
Contents Electronic Theodolites Page Safety Precautions must be followed Distinctive DisplaysPage Contents Contents Precautions BatteryGeneral Storing and environmental conditionsInspection, Adjustment and Repair, Overhaul TransportationStandard Equipment OthersUnpacking and Storing Names of Parts Page Preparation of Power Confirm the correct work by pressing the power switchDisplay Key Operations and DisplayKeyboard Power ON/OFF key Function of each key2 V/% key Page Hold key 4 0SET key 5 R/L key Illumination keyAutomatic Power-off function Remaining battery indicatorOther Functions Special key operations Page Setting of Vertical Angle Setting of 90buzzer Setting of correction of vertical angleSetting of angle measurement Setting of automatic power off function Setting of Angle unitSetting up the instrument Preparation for SurveyingLeveling with the Circular level Leveling with the Plate level Centering with the optical plummet Eyepiece adjustment Object sighting Measurement Horizontal angle measurement rightHorizontal angle measurement left Vertical angle measurement Inspection and Adjustment Instructions on inspection and adjustmentPerpendicularity of plate vial to vertical axis InspectionAdjustment Perpendicularity of circular vial to vertical axis Inclination of reticule graduations Perpendicularity of line of sight to horizontal axis Difference of the vertical angle Optical plummet Optional Accessories Diagonal Eyepiece SB14Specifications TelescopeAngle Measurement Vertical Angle CompensationPower source Water resistant Ambient temperatureDimensions Vertical axisPage Certified