Perle Systems GNS-30CR manual Plug-in power supply units

Page 12

7.1 Plug-in power supply units

The Modem receives its power supply in a wide voltage range (+6V…. +30V) via the power supply connectors,

power interface: internal + / external –supply adaptor:

Object

Description

Current

Parameter

 

Input

Adaptor Input

AC

220V(100~240V)

50Hz

Output

Adaptor Output

DC

6V(±5%)

2A

12

Image 12
Contents NOVACOM wireless User GuideGNS-30CR 1. Safety information Note The warranty does not apply in the event of improper use2. Contents 3. Overview 3.2 Rear View3.1 Front View 4.Product description Wide input voltage range Highly compact, light and powerful Extended AT commands for industrial applicationsSupport band GNS-30CR EGSM900/DCS1800/PCS1900 Data, voice, SMS and faxSecurity systems Traffic system Fleet management Teleservice Telematics Telemetry Remote monitoring Remote control4.2 Applications Remote meter reading Mobile office Vending/POS5. Features Class11W for DCS 1800/PCS Control via AT commandsInput voltage range DC+6….. +30V Dimensions 122 × 68 × 21.6mm Weight approx.165g SIM card 3V or Data interface 9pinRS2325.2 SMS 5.3 DataPoint-to-point MT and MO SMS cell broadcast Text and PDU mode CSD up to 14.4kbps USSD Non-transparent modeConnector for plug-in power supply unit Antenna connector SMA female RS232 interface5.4 Fax 5.5 External interfaces6. Installation 6.1 Package contents6.2 Safety and installation information 7. Interface description7.1 Plug-in power supply units power interface internal + / external -supply adaptor7.2 SIM card holder 7.3 Antenna connector SMA female A quad band antenna GSM850/EGSM900/DCS1800/PCS1900 can befemale coaxial jack Pin assignments7.4 RS232 interface Use and operation e.g. host computer is connected via the RS232 cableconverter which baud rate can support at least 230400bps 8. Startup Operating states/LED The LED display the following states of the ModemState in GSM network 9. AT command control