Omega HH550 manual Print Mode Setting Step:, Clear Record Step:, Decimal Point Setting Step:

Page 17

press 3'SETTING to end setting mode.

3-9 Print Mode Setting Step

Printer work mode setting sequencepress and hold sec into setting mode ￿ press ALARM ￿ press G/T MODE ￿ press 3'SETTING , to end setting mode.

3'SETTING for 3

G/T change

3-10 Clear Record Step

Press

￿

RECORD

+

Power ON in the same time

The LCD should display “dEL”

3-11 Disable StartStopIntv and Setting Step

1. Disable

STARTSTOPINTV

sequencepress and hold

3'SETTING

for 3 sec into setting mode ￿ press START disable

start, stop, intv ￿ press 3'SETTING

to end setting mode.

2. Disable ALARM sequencepress and hold 3'SETTING for 3 sec into setting mode ￿ press STOP disable alarm ￿ press 3'SETTING to end setting mode.

3-12 Decimal Point Setting Step

Shift point setting sequencepress and hold

3'SETTING

for 3 sec to

enter setting mode ￿ press

INTV

to

change

decimal point

position ￿ press 3'SETTING to end setting mode.

 

 

3-13 Consecutive Record and Print Setting Step

Setting sequencepress and hold

3'SETTING

for 3 sec to enter setting

mode ￿ press

TIME

setting

/ ￿ ￿ press 3'SETTING

, to

end setting mode.

 

 

 

 

 

If already in setting MODE, press

TIME

button only.

 

3-14 Reset System Setting Step

Press 3'SETTING +

Power ON

12

Image 17
Contents Page Page Page Contents Battery & Fuse Replacement Environment conditions: Maintenance & ClearingSafety symbols: SET RS-232 General Specification12. G 13. T MAX MIN LUX 18. Fc 19. dB 20. %RH IntvOther parts: HiHi AlarmLoLo Alarm Electrical Specification Name of Each Parts and Positions Parts & ControlsPress and hold this button for 3 sec will into LCD Quick Manual for Easy Set-up Power StatusACV、DCV and DCA Test Setting Alarm Setting Step: Unit Setting Step:Press Stop Assort Real Time Clock , Time/ Date Setting Step:Decimal Point Setting Step: Print Mode Setting Step:Consecutive Record and Print Setting Step: Reset System Setting Step:Record / Print Start and Step Operation Method: How to ConnectsTL-A37 Analog Output Cable Scale Change in Graphic ModeTES-1350 Setup Process Transducer 4-20mA ModeFuse Replacement: Battery & Fuse Replacement 4-1 Battery Check & Replacement:Software Installation: Page Page Click Next Default Settings Page Page Page Page Page Page Page Page Page Page Page Page Page Page Meter Stand alone Operation Page Download Datalogger Graphic Recorder PC Page Page Save data by RS-232 communication port in PC Data ConversionPage Page Page On-Line Operation with PC Page Page Page Page Page Page Page Page Page Page