Omega HH550 manual Battery & Fuse Replacement 4-1 Battery Check & Replacement:, Fuse Replacement:

Page 21

Operation way :

Press INTV + Power ON into Process Transducer (4 - 20 mA) mode. First of all, setting Ref1 “ MAX ” reference value (the “MAX” symbol will be flash),

then press

0

 

 

button to input “ MAX ” reference

 

1/2/3 4/5/6 7/8/9

 

 

 

 

 

 

 

 

0.001 ~ 9999, press

￿

 

button and wait for speaker sound. Then

RECORD

 

the process transducer (4 - 20mA) mode setting is success.

 

 

 

 

Ref1- 0

￿ (A/D Reading-4) = “ LCD ” display value

“ LCD ” display value:

 

16

 

Available for (4mA ~ 20mA) transducer only.

4. BATTERY & FUSE REPLACEMENT 4-1 Battery Check & Replacement

1.As battery power is not sufficient, the , will be shown on LCD replace with six new 1.5V batteries is required.

2.a). Disconnecting test leads.

b).Turning off multimeter with screw-driver. c). Open battery cover.

d). Replace the batteries

e). Cover and secure the battery cover.

4-2 Fuse Replacement

a). Disconnecting test leads. b). Turn off multimeter.

c). Open fuse cover with screw-driver.

d). Remove old fuse and replace with new fuse. e). Cover and secure the fuse cover.

Only 5ψ×20mm fast blow type fuse is allowable.

4-3 Note

To prevent electrical hazard or shock, turn off multimeter and disconnect test leads before removing any cover.

5. DATALOGGING

Image 21
Contents Page Page Page Contents Battery & Fuse Replacement Maintenance & Clearing Safety symbols:Environment conditions: SET RS-232 General Specification12. G 13. T MAX MIN LUX 18. Fc 19. dB 20. %RH IntvHiHi Alarm LoLo AlarmOther parts: Electrical Specification Name of Each Parts and Positions Parts & ControlsPress and hold this button for 3 sec will into LCD Power Status ACV、DCV and DCA Test SettingQuick Manual for Easy Set-up Alarm Setting Step: Unit Setting Step:Press Stop Assort Real Time Clock , Time/ Date Setting Step:Decimal Point Setting Step: Print Mode Setting Step:Consecutive Record and Print Setting Step: Reset System Setting Step: Record / Print Start and Step Operation Method: How to ConnectsTL-A37 Analog Output Cable Scale Change in Graphic ModeTES-1350 Setup Process Transducer 4-20mA ModeFuse Replacement: Battery & Fuse Replacement 4-1 Battery Check & Replacement:Software Installation: Page Page Click Next Default Settings Page Page Page Page Page Page Page Page Page Page Page Page Page Page Meter Stand alone Operation Page Download Datalogger Graphic Recorder PC Page Page Save data by RS-232 communication port in PC Data ConversionPage Page Page On-Line Operation with PC Page Page Page Page Page Page Page Page Page Page