Omega Engineering IOP-241 user manual Enabler Installation

Page 16

2.2.1Enabler Installation

The following procedure is used to install the IOP-241 Enabler:

1.Copy the file IOP241EN.EXE from the customer software CD-ROM (directory=PCMCIA\DOS\ENABLERS) onto the root directory of the system hard drive.

2.Using an ASCII text editor, open the system's CONFIG.SYS file located in the root directory of the boot drive.

3.Locate the line(s) in the CONFIG.SYS file where the Card and Socket Services software is installed.

4.AFTER the line(s) installing the Card and Socket Services software, add the following to the CONFIG.SYS file: DEVICE = drive:\path\IOP241EN.EXE(options), where options are the IOP-241 Client Driver command line options discussed on the following pages. (Path is only required if the Enabler executable file is placed in a directory other than the root directory).

5.Save the CONFIG.SYS file and exit the text editor.

6.Insert the IOP-241 into one of the system's PCMCIA slots.

NOTE: Since the IOP-241 Enabler does not support "Hot Swapping", it is necessary to have the IOP-241 installed when booting the system.

7.Reboot the system and note the message displayed when the IOP-241 Enabler is loaded. If the Enabler reports an "invalid command line option", correct the entry in the CONFIG.SYS file and reboot the system again. If the Enabler reports the desired card configuration, the installation process is complete.

IOP-241 Users Manual

16

Image 16
Contents 15,1*,1 WARRANTY/DISCLAIMER Manufacturers Name Manufacturer’s AddressApplication of Council Directive Standards to which Conformity is DeclaredFor immediate technical or application assistance Servicing North AmericaServicing Europe Page Table of Contents Page List of Figures and Tables IOP-241 Features System ConfigurationClient Driver recommended Enabler IOP-241 Client Driver for DOSClient Driver Installation Command Line Options Device = C\IOP241CL.SYSPage Common Problems IOP-241 Enabler for DOS Enabler Installation DEVICE=C\IOP241EN.EXE Common Problems After Completing Configuration Installing the IOP-241 Under Windows 95/98 Resource Settings in Windows 95/98Changing Resource Settings with Device Manager After Completing Configuration I/O Port Description Port C Interrupt Description External Interrupt DescriptionData Port a Control Register Base + Offset Read/Write RegisterData Port B Control Register Base + Data Port C Control Register Base +Port C Interrupt Enable Register Base + Bit Name DescriptionInterrupt Mode Control Register Base + Interrupt Status Register Read Only Base +Summary of Interrupt Source Options Interrupt Acknowledge Register Write Only Base +Port C Interrupt Sources Summary of Input/Output Options External Interrupt SourceProgramming Example External Connections Optional Accessories CP-1037 Cable AssemblyUIO-37 Screw Terminal Block Physical Dimensions Power RequirementsConnector Bus InterfaceVersion January 25