Page 19

2.2.3.3 Card and Socket Services Software

In order to use the IOP-241 Enabler for DOS, the system MUST NOT be configured with Card and Socket Services software. If Card and Socket Services software is installed, the IOP-241 Enabler may interfere with its operation and with the device(s) it controls. For systems configured with Card and Socket Services, the IOP-241 Client Driver is the recommended method of configuration.

2.3After Completing Configuration

The IOP-241 is now configured and ready for use. Depending on the type of application software to be used, the user may wish to review one or more of the following:

1.Chapter 4 of this document provides a basic theory of operation of the card for users that wish to learn the technical details about the operation of the IOP-241.

2.For users that want to program the IOP-241 with direct I/O transfers to the card’s register set, Chapter 5 provides an address map and a detailed description of each I/O register.

3.Users that wish to write custom application software without programming the IOP-241 directly should consult the DAQDRIVE software reference manual. DAQDRIVE provides a library of data acquisition subroutines and is included free of charge with the IOP-241.

4.For third party data acquisition software such as LabTech Notebook®, LabVIEW®, TestPoint® or SnapMaster®, consult the documentation provided by the software manufacturer.

IOP-241 Users Manual

19

Image 19
Contents 15,1*,1 WARRANTY/DISCLAIMER Standards to which Conformity is Declared Manufacturers NameManufacturer’s Address Application of Council DirectiveFor immediate technical or application assistance Servicing North AmericaServicing Europe Page Table of Contents Page List of Figures and Tables System Configuration IOP-241 FeaturesIOP-241 Client Driver for DOS Client Driver recommended EnablerClient Driver Installation Device = C\IOP241CL.SYS Command Line OptionsPage Common Problems IOP-241 Enabler for DOS Enabler Installation DEVICE=C\IOP241EN.EXE Common Problems After Completing Configuration Resource Settings in Windows 95/98 Installing the IOP-241 Under Windows 95/98Changing Resource Settings with Device Manager After Completing Configuration I/O Port Description External Interrupt Description Port C Interrupt DescriptionOffset Read/Write Register Data Port a Control Register Base +Data Port C Control Register Base + Data Port B Control Register Base +Bit Name Description Port C Interrupt Enable Register Base +Interrupt Status Register Read Only Base + Interrupt Mode Control Register Base +Summary of Interrupt Source Options Interrupt Acknowledge Register Write Only Base +Port C Interrupt Sources External Interrupt Source Summary of Input/Output OptionsProgramming Example External Connections CP-1037 Cable Assembly Optional AccessoriesUIO-37 Screw Terminal Block Bus Interface Physical DimensionsPower Requirements ConnectorVersion January 25