5.4Port C Interrupt Enable Register (Base + 5)
INT7 - INT0 may be enabled by writing the appropriate bits in the Port C Interrupt Enable Register. The corresponding I/O channel must be configured as an input channel via the Data Port C Control Register if an interrupt is to be generated. If an I/O channel is configured as an interrupt source (INT7 - INT0), the I/O channel continues to be a standard data input channel (DATA23 - DATA16) and may be read just as any other input signal is read.
| Bit | Name | Description |
|
|
| |||
|
|
|
|
|
| 7 | INT7EN | 1 = Enables INT7; 0 = Disables INT7 |
|
|
|
|
|
|
| 6 | INT6EN | 1 = Enables INT6; 0 = Disables INT6 |
|
|
|
|
|
|
| 5 | INT5EN | 1 = Enables INT5; 0 = Disables INT5 |
|
|
|
|
|
|
| 4 | INT4EN | 1 = Enables INT4; 0 = Disables INT4 |
|
|
|
|
|
|
| 3 | INT3EN | 1 = Enables INT3; 0 = Disables INT3 |
|
|
|
|
|
|
| 2 | INT2EN | 1 = Enables INT2; 0 = Disables INT2 |
|
|
|
|
|
|
| 1 | INT2EN | 1 = Enables INT1; 0 = Disables INT1 |
|
|
|
|
|
|
| 0 | INT1EN | 1 = Enables INT0; 0 = Disables INT0 |
|
|
|
|
|
|
|
|
|
|
|