Glossary
Page 24 | WI1501A 9/06 |
E19 - Lug E19 is the Listen in Lug. It is an input and when it is forced low the panel will silence the keypad/Touchpad sounder and bell outputs so that the
Easy Exit
While armed in the Interior Mode, Easy Exit can be initiated by pressing STAY. Easy Exit restarts the Exit delay, allowing a User to exit an armed premises without disarming and rearming the system.
Easy
Easy Programming of Auto download ID #'s and PC Preset Callback #
It is now possible to set the PC Preset Auto download ID # and PC Preset Callback phone number from the
1.Enter the Easy Menu Driven Program Mode and press PRIOR/NO until Central Phone # is displayed.
2.Program an "F" followed by the Auto Download ID # (2 digits) and then the Callback Telco # (up to 13 digits).
3.Press Uto save.
4.Exit Program Mode (press RESET, RESET).
5.Remove the
6.Insert the Master
7.Go to Function "ACTIVATE DOWNLOAD Y/N" and press YES.
8.The panel will automatically call the PCPreset computer and download the program on the specified Auto DL line #.
Note: After the auto download of the control panel program, the system must be fully tested.
See following example:
Example: Program an Auto Download ID # of 07 and a PC Preset Callback # of
• Go to Central Phone # input screen and press: [*] [5] | [0] [7] | [1] [5] [1] [6] [8] [4] [2] [9] [4] [0] [0] | [ON/OFF] |
("F") | (Auto DL ID#) | (Callback Phone #) | (Save) |
Enable Alarm Output on Telco Fail only when Area(s) Armed (Alarm Output Only when Armed)
Allow Telephone Line Fault test to produce an Alarm Output only when armed. Note: Requires "System Features: Alarm Output", "Telco Fail" and version 9 or later panel.
Enable
Enable CP-01 Limits
When enabled, three time limits are enabled as per the SIA
Note: In accordance with UL standards, the aggregate of the Entry Delay time and Abort Delay time "window" will not be programmed to
exceed one minute. Note: When "Enable
during the final 10 seconds of the Exit Delay) is enabled only when keypads are used. Note: If "Enable
Enable Keypad 1 Only Programming: In version 01 of the
Enable Local Alarm on First Zone "AND" Trip See Zone ANDing (Do not program in UL installations)
Enable TCP/IP Communications
Using the NetLink