Duress Code. The panel will not allow duplicate User Codes to be programmed. Every user program code may now be

New Operation of the Panel

selected as an Ambush Code for Area 1 or Area 2 by entering a _5 in the Area 1 Options or Area 2 Options respectively.

 

 

Note: Keypad(s) must be enabled for Ambush.

 

 

Cross Zoning. Required Option for cross zoning with either programmable time period or specified by manufacturer. De-

Pre-existing feature

fault is disabled. The existing programmable by zone feature "Zone ANDing Groups" are available for the cross zoning

 

 

option required by CP-01. This feature is not enabled in the factory program and not enabled when Enable CP-01 Features

 

 

are enable in the Easy Menu Driven Program Mode. Cross Zone set time = one (1) minute.

 

 

Swinger Shutdown. Zone will only trip once and will not restore automatically. "Auto-Reset" (Addresses 0917, 0981,

Pre-existing features

1045, 1109, 1173, 1237, 1301 and 1356) and "Swinger Shutdown" (Addresses 0918, 0982, 1046, 1110, 1174, 1238, 1302

 

 

and 1366) are disabled in order to meet the CP-01 requirement of only one alarm activation per zone during an arming pe-

 

 

riod. These features are not selected on zones 1-8 in the factory program and are removed from all zones when "Enable

 

 

CP-01 Features" is selected in the Easy Menu Driven Program Mode. In a SIA CP-01 installation, these options must not

 

 

be selected. Auto-Reset must be programmed for all burglary zones in a UL Installation. See the glossary entry,

 

 

"Swinger Shutdown" in this manual.

 

 

Fire Alarms. Fire Alarm Verification available option on Fire Zones. Default is disabled. The existing programmable option

Pre-existing feature

"Fire Alarm Verification" is available as required by CP-01. This feature is not enabled in the factory program and not en-

 

 

abled when "Enable CP-01 Features" is selected in the Easy Menu Driven Program Mode.

 

 

Call Waiting. Disable Call Waiting on 1st Attempt. Default is disabled. When enabled, the telephone number must

2053, Bit 5 (see Note 2)

be programmed with *70 in front of the telephone number. The first attempt will dial with *70 (disabling call waiting).

(2053

· · · · · 6 · ·)*

Subsequent attempts (if first attempt is unsuccessful) will dial without *70. Note: The digits used to disable Call

 

 

Waiting may vary with location. Be sure to confirm with local telephone company. Note: Disabling Call Waiting on a

 

 

non Call-Waiting line can result in a delay in the connection to Central Station.

 

 

System Test. Test Mode for all zones, the sounders, and communicator. The "Fault Find" function (a Touchpad/

 

 

Function Menu selection) is enabled, and normally causes all hardwired zones to give a two second beep at the F-

 

 

64PROG programmer(s) when any zone is faulted or restored. As required by SIA CP-01, Fault Find is expanded with

 

 

the following features when Digital Dialer Report Enter/Exit Test Mode is programmed. This option is programmed

2053, Bit 4 (see Note 4)

when "Enable CP-01 Feature" is selected in the Easy Menu Driven Program Mode:

(2053

· · · · 5 · · ·)*

When Fault Find is entered, it reports to Central Station that "Test Mode" is in progress.

 

 

Fault Find can not be initiated from an armed panel, and all digital dialer reporting in same area is inhibited while in Fault Find.

Fault Find Central Station Reporting Code is located at address 2053.

Keypad will display the following warning that the system is in Fault Find: "FAULT FIND RF SIG POWER - - "

If a 24-hour zone is tripped and not restored during Fault Find, when the mode is exited the zone will display as "Faulted" on the keypad display.

When Fault Find is exited by pressing C, a Fault Find Restore Report will be sent.

Notes:

Note 1: This feature is enabled in the factory program and is enabled when "Enable CP-01 Features" is selected in the Easy Menu Driven Program Mode. This feature must be enabled in CP-01-compliant installations.

Note 2: This feature is not enabled in the factory program and is not enabled when "Enable CP-01 Features" is selected in the Easy Menu Driven Pro- gram Mode.

Note 3: This feature is enabled in the factory program and is enabled when "Enable CP-01 Features" is selected in the Easy Menu Driven Program Mode. This feature must be programmed in CP-01-compliant installations if a GEM-KEYF is used in the system.

Note 4: This feature is programmed when "Enable CP-01 Features" is selected in the Easy Menu Driven Program Mode.

At least one Exit/Entry zone must be programmed for each area. (SIA CP-01 Specification 4.2.1)

The F-64 control panel and at least one Gemini "K Series" keypad must be installed.

The following optional accessories support the SIA False Alarm Reduction (FAR) classification, and may be used if desired: GEM-EZOUT8, GEM- EZM8, GEM-EZM4/8, GEM-RECV8/16/32, GEM-TRANS2, GEM-KEYF.

Programming at Installation may be subordinate to other UL requirements for the intended application.

Un-vacated premises: When the system/partition is armed with AWAY button, the system will arm STAY if no exit. There must be a minimum of one Stay/Away or Delay Stay/Away zone enrolled on the partition.

Cross zoning is not recommended for Line security Installations nor is it to be implemented on exit / entry zones.

There is a Communication Delay of 30 seconds in this control panel. It can be removed, or it can be increased up to 45 seconds at the option of the end user by consulting with the Installer.

Do not duplicate any reporting codes. This applies for all communication formats other than SIA sending automatic programmed reporting codes.

In UL installations, Entry Delay time plus Abort Delay time (total combined times) cannot exceed 60 seconds.