Napco Security Technologies WI1501A Earth Ground, Wiring Connections Remote Bus

Models: WI1501A

1 44
Download 44 pages 7.1 Kb
Page 12
Image 12
REMOTE BUS

Page 12

WI1501A 9/06

REMOTE BUS

& Earth Ground

REMOTE BUS

ADDITIONAL

EZMs

(GEM-RP1CAe2)

2 LINE KEYPAD

Example:

F-64TP Touchpad

NOTE: Refer to the EZM Installation Instructions for specific wiring information.

AVAILABLE DEVICES

AVAILABLE DEVICES

1. KEYPADS: GEM-RP2AS & GEM-RP1CAe2

 

2. X-10 INTERFACE: GEM-X10

1.

TOUCHPADS / KEYPADS: (3 maximum) F-64PROG:32-Character

3. WIRED ZONE EXPANDER: GEM-EZM816LCD Burg

& Fire Programmer*, F-64TP:Wireless Touchpad, F-

 

 

4. WIRELESS RECEIVERS: GEM RECV8,64TPGGEM-RECV16Garage&DoorGEM-RECV96Touchpad*,F-64TPBRBedroom Touchpad, F-

5. RELAY MODULE: RM3008

 

64TP-HHardwired Touchpad*

6. VOICE INTERFACE: GEM-EVA

 

 

 

7. TELEPHONE INTERFACE: WIZARD2. X-10 INTERFACE: GEM-X10 (16 devices maximum)*

3. WIRED ZONE EXPANDER: GEM-EZM4/8EX*, GEM-EZM4/8* (64 zones maximum)

4. WIRELESS RECEIVERS: GEM-RECV8, GEM-RECV16, GEM- RECV96 (64 zones maximum)

5. RELAY MODULE: RM3008 (16 relays maximum)

6. VOICE INTERFACE: GEM-EVA 1*

7. TELEPHONE INTERFACE: WIZARD IIe*

Wiring Connections: Remote Bus

Connect the available devices as shown above to the remote bus terminals (9, 10, 11 & 12). Observe the correct color wire connections. When connecting the Touchpads, first configure them accordingly (refer to the Touchpad Configuration Mode in WI1502). Up to four Touchpads may be connected if the longest cable run from the panel, to the farthest Touchpad (daisy chained or home-run) is less than 1000 feet. The maximum distance for seven key- pads/Touchpads is 300 feet using 22 AWG. wire. NOTE: When running keypad/Touchpad wire, avoid wiring parallel to other types of wiring.

EARTH GROUND

Connect the control panel EARTH GROUND screw to a metal cold-water pipe using at least a #16 AWG. wire. Do not use a gas pipe, plastic pipe or AC ground connections. Also, connect the circuit board to the metal enclosure. Connect a wire with a ground lug crimped or soldered onto one end of the EARTH GROUND screw to the cabinet.

NOTE: Grounding connections should avoid bends in the grounding wire whenever possible.

NOTE: Do not use a gas pipe, plastic pipe or AC ground connections.

* Not evaluated by UL

Freedom F-64 Installation Instructions

L NAPCO Security Systems

 

Page 12
Image 12