4. Register Description and Programming

The DAQ-12 uses 16 consecutive I/O address locations in the range 0 to FFFFH. The card utilizes these addresses for the registers listed in Table 4-1. (* indicates registers located in 8254 counter).

 

Base + 0, 1

Read/Write 16-bit Control Word Register

 

 

 

 

 

 

 

 

 

Base + 2, 3

Write only

16-bit Start Conversion Register

 

 

 

Read only

16-bit A/D Data Register

 

 

 

 

 

 

 

Base + 4, 5

Write only

16-bit D/A Channel 0 Register

 

 

 

 

 

 

 

Base + 6, 7

Write only

16-bit D/A Channel 1 Register

 

 

 

 

 

 

 

 

Base + 8

Read/Write

8-bit

Digital Input/Output Register

 

 

 

 

 

 

 

 

Base 9

Read/Write

8-bit

Gain Control Register

 

 

 

 

 

 

 

 

Base A, B

Reserved

 

 

 

 

 

 

 

 

 

 

Base + C *

Read/Write

8-bit

Clock Rate Register (low)

 

 

 

 

 

 

 

 

Base + D *

Read/Write

8-bit

Clock Rate Register (high)

 

 

 

 

 

 

 

 

Base E *

Read/Write

8-bit

Multi-function Timer Register

 

 

 

 

 

 

 

 

Base F *

Read/Write

8-bit

8254 Control Word/Status Register

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 4-1. DAQ-12 Address Map

4.1Register Description

4.1.1Control Word Register

The control word register defines and controls many of the DAQ-12'S data conversion functions. This register is 16-bit read/write.

 

Write

Read

 

Write

Read

D15

INT2

INT2

D7

RUN

RUN

D14

INT1

INT1

D6

0

EOC

D13

INT0

INT0

D5

0

VALID

D12

DMAEN

DMAEN

D4

DMASL

DMASL

D11

DMACT

DMACH

D3

CHSL3

CHSL3

D10

LEVEL

LEVEL

D2

CHSL2

CHSL2

D9

TRIG

TRIG

D1

CHSL1

CHSL1

D8

CLK

CLK

D0

CHSL0

CHSL0

DAQ-12 Users Manual

25

Image 25
Contents 15,1*,1 WARRANTY/DISCLAIMER Manufacturer’s Address Manufacturers NameApplication of Council Directive Standards to which Conformity is DeclaredFor immediate technical or application assistance Servicing North AmericaServicing Europe Page Table of Contents Introduction List of Figures and Tables Installation DAQ-12 Specifications Analog to Digital Converter Jumper J1 ConfigurationDisable Pre-Scaler Enable Pre-Scaler Factory default Recommended Input Ranges and Gain Settings Code Voltage Unipolar Bipolar Code Digital to Analog ConvertersGain = Channel BipolarBase Address Digital Input/OutputClock Selection Internal Clock External Clock Start of Conversion Trigger Selection10. Jumpers J8 and J9 Configuration Dack Direct Memory AccessExternal Interrupt InterruptsExternal Connections Page Control Word Register Register DescriptionINT2 INT1 INT0 Description 3 A/D Converter Data Register Start of Conversion Register4 D/A Converter 0 Register Multi-Function Timer Register5 D/A Converter 1 Register Clock Rate Register low wordProgramming the 8254 Counter/Timer Counter 1 Clock rate register high word Version January 28