ANALOG OUTPUT OPTION
Description:
An optional
Connections: (see FIG. 1)
PIN13 supplies the 12 to 18 VDC to power the current loop. PIN14 is the control sink driver
Accuracy: 50uA worst case
Compliance Voltage:
3 to 30 VDC non conductive
Setup:
The optional analog output feature uses 4 dip switches on the back for setup. These switches are used as follows:
SW1 - View or change "set low" and/or "set high" values SW2 - Select output for rate or total
SW3 - Select
After the regular parameters shown in the programming flowchart have been set, locate the 4 switches on the back of the unit. (see FIG. 1)
Switch Settings:
SWITCH 1: Enter Analog Low & High (normally off)
Switch 1 is used to load in the low (4mA or 0mA) and/or the high (20mA) output settings. With power on, set switch 1 ON (up).
LOW SETTING is viewed or changed by pressing PRE A. If the displayed value is correct, press ENTER. If not, press buttons A through E to step to the desired value and press ENTER. (disre- gard the display which will show the last count reading).
HIGH SETTING is viewed or changed by pressing PRE B. If the displayed value is correct, press ENTER. If not, press buttons A through E to step to desired value and press ENTER.
Return switch 1 to OFF (down) position, PRE A and PRE B buttons now function to view or change relay trip values.
SWITCH 2: Select Count or Rate
SW2 OFF (down): Analog output follows rate
SW2 ON (up): Analog output follows count
SWITCH 3: Select
SW3 OFF (down): Selects
SW3 ON (up): Selects
SWITCH 4: Calibrate (normally off)
Switch 4 is used for calibration. Calibration is done at the factory and should not be needed (see SWITCH 1 to enter high and low values). If recalibration is desired, a calibrated 20mA ammeter with 1uA resolution is needed. Attach the "+" lead of the meter to pin 13 and the
RS232 & RS422 Operation:
When the unit is suppled with RS232 or RS422, the analog output "low" and "high" settings can be accessed and changed through the serial port. The codes are as follows:
AL Unit will display (transmit) analog out "low" value. AL(S)XXXXX Unit will load analog out "low" with entered
number. (S) = space
AH Unit will display (transmit) analog out "high" value. AH(S)XXXXX Unit will load analog out "high" with entered
number. (S) = space
FIG. 1
Analog Out |
|
| Serial Port |
| Setup Switches | |||||||
13 | 14 |
|
|
|
|
|
|
| 4 | 3 | 2 | 1 |
|
|
|
|
|
|
|
|
|
| ON | ||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| REAR | VIEW |
|
|
| |||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 12 |
Typical Wiring:
RELAYA | COM. | 1 |
| |
RELAYA | N.O. | 2 |
| |
RELAY B | COM. | 3 |
| |
RELAY B | N.O. | 4 | PULSE OUTPUT | |
INPUT A | 5 | |||
| ||||
INPUT B | 6 | +12V | ||
11 to 19V @50mA OUT/ +DC IN | 7 | |||
GND | ||||
8 | ||||
| ||||
RESET INPUT | 9 |
| ||
6 to 14V @ 50mA 10 |
| |||
110 / 220 VAC | 11 | TURBINE FLOWMETER | ||
110 / 220 VAC | 12 | |||
| ||||
11 to 19V OUT 13 | + | |||
| ||||
ANALOG OUT (SINK) 14 | - | |||
|
|
|