DESCRIPTION & SPECIFICATIONS

DESCRIPTION:

The OMEGA DPF70 is a dual input (channel A and B) counter/ ratemeter, each with its own 5 digit dividing scale factor. The two 5 AMP preset relay outputs can be programmed by the user to apply to the "A" total counter, the "A" ratemeter, or the "B" counter or the net total of A and B inputs. The user can view the Net Total of "A+B", the Net Total of "A-B", the rate of A, or A and B counters separately. The "DPF75" version shows rate and total (as de- scribed above). The "DPF76" is exclusively a counter and the "DPF78" is exclusively a ratemeter.

SPECIFICATIONS:

DISPLAY

6 digit, 0.55" High LED

INPUT POWER:

110 VAC ± 15% or 11 to 15 VDC

220 VAC ± 15% or 11 to 15 VDC

CURRENT:

250 mA DC max. or 6.5 VA AC

OUTPUT POWER (AC powered units only) +12 VDC @ 50 mA, unregulated -10 + 50%

TEMPERATURE:

Operating: +32°F (0°C) to +130 F (+54°C)

Storage: -40 F (-40°C) to +200°F (93°C)

DIMENSIONS: See next page.

WEIGHT:

2 Lbs. (1 kg)

MEMORY

EEPROM stores data for 10 years if power is lost.

INPUTS:

3:High Impedance DC pulse input Open or 0-1 VDC

(low), 4-30 VDC (high), 10 KOhm imp. 10 KHz max. speed. Accepts simultaneous inputs.

3M: Mag. Input, Input A only, accepts 30mV input (50 V max. P/P) signals 10 KOhm imp. 5 KHz max. (Input B, 4-30V)

3MB: Mag. Input, Inputs A & B, accepts 30mV input (50 V max. P/P) signals 10 KOhm imp. 5 KHz max.

5:4-30 V Count pulses on Input A, 4-30 V Direction

Control input (level) on Input B.

5M: 30 mV Count pulses on Input A (50 V max. P/P) 4-30 V Direction Control input (level) on Input B

9:Quadrature, accepts 4-30 V pulses with 90°phase shift for direction detection.

9MB: Quadrature, accepts 30 mV (50 V max. P/P) pulses with 90°phase shift for direction detection.

NOTE: The Mag. inputs have filtering as follows: up to 300hz @30mV, 5KHz @ .25V to 50V max.

RESET: Front Panel:

Resets displayed value and control output Remote:

4-30 VDC negative edge resets COUNTER "A" and control output

K FACTOR/SCALING

In the standard unit a fixed K-Factor is used to convert the input pulses to engineering units. The 5 digit K-Factor dividers, with decimal keyed into any position, allow easy direct entry of any K- Factor from 0.0001 to 99999. Separate factors may be entered for the 2 separate input channels.

CONTROL OUTPUTS:

Relays:

2 each N.O. Relay; 5 Amps120/240 VAC or 28 VDC. (N.C. relay contacts and NPN transistor output available with solder jumpers. Transistor output is internally pulled up to 10 VDC through relay coil, sinks from 10 VDC to .5 V @ 100 mA)

Analog Output:

An optional 4-20mA (0-20mA) output is available for the DPF70 series. The output can be programmed to track rate or total. This feature is available by adding suffix A to the part number. Connections are via a 2 terminal pluggable screw connector. Programming is accomplished by using the front panel in conjunction with rear dip switches.

Accuracy: 50uA worst case.

Compliance Voltage: 3 to 30 VDC non inductive.

RS232/RS422SERIAL INTERFACE

If the serial interface option is supplied, up to 99 units can be linked together. (The terminal addressing the unit must be capable of driving all loads in the loop.) Unit status and new set points can be communicated by serial communication. Mode changes, however, must always be made on the front panel. Data is transmitted at selected baud rates using standard seven bit ASCII characters and parity with two additional bits of “Start” and “Stop” to make up the standard ten bit character.

Data is received and transmitted over standard EIA RS232 or RS422 levels. Each 10 bit character is made up of a start bit, 7 bit ASCII code, parity bit and stop bit. Unit number, baud rate and parity are entered in the “Program Setting” set up mode and remain in memory even if power is off.

Note that the input impedance of RS232 is 3K or 7K Ohm worst case. The terminal addressing the unit must be capable of driving all loads in the loop. RS422 input impedance is much higher and there is usually no problem driving 25 units. Unit serial transmit line remains in a high impedance “OFF” state until addressed.

PRESETS

Two control outputs are provided. To set relay values, press “menu” button until “Relay” appears on the display, the A and B outputs can be assigned to the ratemeter (high/low), one preset for rate and one for total, or two presets (2 stage shut off) on the A and B counters. A 5 digit value can be entered for both presets and the decimal point location is the same as the counter. The outputs can be set to energize from 0.1 to 99.9 seconds or latch (0.0). If a value other than 0.0 is entered, the counters will auto reset at the preset . In the A-B or A+B versions, the relays will be assigned to either net total or A rate.

LOCKOUT

Unauthorized front panel changes can be prevented by entering a user selected 5 digit code, in the “LOC” , . mode. The front panel can be completely locked out or the presets can remain accessible.

RATEMETER

Accurate to 4 1/2 digits (±1 display digit). The rate meter can be programmed to accept almost any number of pulses per unit of measurement, sample from 2 to 24 seconds maximum, and auto- range up to 5 digits of significant information. In the “RPS” mode, the ratemeter displays in units per second, and in the “scale” mode, units per hour or per minute. The unit will display the rate of the A Input only.

COUNTER

The two 6-digit counters can count at 10Khz speed. Each can have a 5-digit dividing scale factor. The counter advances on the positive edge of each pulse. Count up or down modes available, as are quadrature inputs from encoders for position or length mea- surement. The unit can be programmed to view the net value of "A+B" or "A-B", or A and B as separate counters.

1

Image 6
Contents User’s Guide For immediate technical or application assistance Table of Contents Quick SET-UP Guide Programming ExampleCounter DPF75, DPF76 Description & Specifications DescriptionHOW to Mount the Unit DimensionsQuadrature Input WiringUP/DOWN Control and Quadrature Inputs UP/DOWN ControlConnecting AC / DC Power Wiring Considerations Do not USE PIN 7 with These Meters=CLOSE, O=OPEN What can YOU VIEW?Output Jumper Selections Millivolt Input Option 30V InputProgramming Flowchart Operating the Front PanelProgram Program Codes and Descriptions Portion of Menu for Setting Counter VariablesPortion of Menu for Setting Rate Variables DescriptionTerminations Rear ViewCalculating Scale Factors Scaling Factor ExamplesRemarks ProgrammingPress ScalingSetting Counter PrgmSetting Rate Remarks DisplaySetting LockLock Setting Relays PresetsRemarks Press Output Wiring AlarmsAnalog Output Analog Output Option DescriptionInterface Card RS 232/422 Operation Placed in ANY of These Data Values Serial Input CommandsUnit will Recognize a Decimal if ONE is †THE Unit will only Recognize the Last FiveDP -9 Connector Computer Computer HookupPrinter Hookup Troubleshooting Guide Problem Possible Causes SolutionsPage Page Page WARRANTY/DISCLAIMER Temperature