Omega Speaker Systems VR200 instruction manual Format MDp1, p2, p3, Example MD02, ON, on

Page 20

 

2.2 Program Set Commands

 

If your model has -3M option, add the parameter p3.

p3:

Select the methods when saving measurement data to the floppy disk:

 

ALL (default) save all measurement data from the VR200 internal memory.

 

UNSAVED: Save only the meansurement data newly loaded to the VR200

 

internal memory, after the last time you saved to the floppy disk.

2.20Waveform Display and Scale Display Setting (DISP_WAVE, for the VR 200 with style number 2 or higher)

(see section 4.7.3 in the instruction manual)

Format: MDp1, p2, p3

p1:

Channel number (CC)

p2:

Turn ON/OFF the waveform display

p3:

Turn ON/OFF the scale display

Example: MD02, ON, ON

2 RECEIVING FUNCTIONS

2 - 9

Image 20
Contents User’sGuide Servicing North America Preface TrademarksContents Program Examples Time Chart Initial Status Errors During RS-422-A OutputTransmitting Functions Installing the RS-422-A Interface Interface SpecificationsInterface Terminal Terminal Assignment Cable TerminationCommunication Wiring Data ConfigurationStart-stop Asynchronous Communication TextInput Buffer Buffer OverflowSetting up the RS-422-A Communication Interface Setup ProcedureTerminator IdentifierParameters List of Program Set Commands Setting the Range and ScaleFormat SRp1,mode Example SR01,SKIPFormat SRp1, mode, p2, p3, p4, p5, p6, p7, p8 Format SRp1, mode, p2Example SR01, DI, Setting Alarms Setting the Unit Setting the Waveform Span Rate TIME/DIVSetting the Clock Copying the Channel SettingsSetting the Tag Setting the Discrete Zone DisplaySetting the Partial Expanded Display Setting the Trip Level Setting the Data File Name FileSetting the LCD Brightness and LCD Saver LCD Setting the Summer/ Winter Time DSTFormat MDp1, p2, p3 Example MD02, ON, onList of Program Control Commands Alarm AcknowledgeStandard Screen Call Initializing the Data MemoryLoading the SET Configuration File Saving the SET Configuration FileSelecting the Output Data Selecting the Output Format for Measured DataMessage Writingfor the VR 200 with style number 2 or higher Requests for the data to be prepared in the buffer Execution of TriggerStatus Output Open Command Close CommandESC O Crlf ESC C CrlfIntroduction to Output Data Formats Sequence see also Sections 2.3.7Output Format of Measured Values in Ascii Mode Output Data FormatsOutput Format of Measured Values in Binary Mode Output Format of Parameter Settings Output Format of Unit and Decimal Point Information Time Chart Initial Status Preventing Errors OutputHow to Request Error Message Output ESC S CR LFTiming of Resetting the Error Status Program Examples EnvironmentOpen TEST.DAT for Input AS #2 Others LF is sent automatically 210 ‘ 220 ‘ Open COM11200,N,8,1,LF AS #1 Print a Appendix Appendix 1 Ascii Code TableAppendix 2 File Naming Rules File Name LengthLowercase/Uppercase Letters System-reserved File NamesIndex Index for Command Reference Warrant Y/ Disclaimer Temperature