Appendix A - Troubleshooting

Appendix A - Troubleshooting

A Serial Utility Diskette is supplied with the Omega Engineering adapter and will be used in the troubleshooting procedures. By using this diskette and following these simple steps, most common problems can be eliminated without the need to call Technical Support.

1.Identify all I/O adapters currently installed in your system. This includes your on-board serial ports, controller cards, sound cards etc. The I/O addresses used by these adapters, as well as the IRQ (if any) should be identified.

2.Configure your Omega Engineering adapter so that there is no conflict with currently installed adapters. No two adapters can occupy the same I/O address.

3.Make sure the Omega Engineering adapter is using a unique IRQ. While the Omega Engineering adapter does allow the sharing of IRQs, many other adapters (i.e. SCSI adapters & on-board serial ports) do not. The IRQ is typically selected via an on-board header block. Refer to the section on Card Setup for help in choosing an I/O address and IRQ.

4.Make sure the Omega Engineering adapter is securely installed in a motherboard slot.

5.When running DOS, Windows 3.x or other operating systems refer to the Serial Utilities Disk 1 and the User Manual to verify that the Omega Engineering adapter is configured correctly. The supplied software contains a diagnostic program 'SSD' that runs under DOS and will verify if an adapter is configured properly. This diagnostic program is written with the user in mind and is easy to use. Refer to the README.txt file on the supplied diskette for detailed instructions on using 'SSD'.

6.For Windows 95/98 and Windows NT, the diagnostic tool 'WinSSD' is installed in the Omega Engineering folder on the Start Menu during the setup process. First find the ports using the Device Manager, then use 'WinSSD' to verify that the ports are functional.

Always use the Omega Engineering diagnostic software when troubleshooting a problem. This will help eliminate any software issues and identify any hardware conflicts

Omega Engineering COMM+232.PCI

Page 11

Image 15
Contents User’sGuide Czech Republic CanadaMexico BeneluxContents Figures What’s Included Factory Default SettingsIntroduction OverviewCard Setup Address and IRQ selectionClock Modes For this Data Rate Choose this Data Rate Baud Rates and Divisors for the ‘DIV2’ modeOmega Engineering COMM+232.PCI Clocking Mode Divide By 1’ Baud Rates and Divisors for the ‘DIV1’ modeOmega Engineering COMM+232.PCI Windows InstallationOperating System Installation Windows 95/98/NT Hardware InstallationInterrupts Technical DescriptionConnector Pin Assignments RS-232 Why use an ISP?Specifications Appendix a Troubleshooting Appendix B How To Get Assistance Appendix C Electrical Interface Appendix D Asynchronous Communications Asynchronous Communications Bit DiagramAppendix E Silk-Screen Appendix F Compliance Notices WARRANTY/DISCLAIMER Temperature