Miller Electric Remote Operator Interface manual Indicates a trigger, Closed error

Page 30

7-2. Diagnostics (Continued)

WELD

WAIT

Indicates a weld cycle wait error.

MOTR

COM

Indicates a motor communication error.

PLS

WAIT

Indicates a UIM communication error.

OVER

CRNT

Indicates an overcurrent error.

LOW

WFS

Indicates a low WFS command error.

E

STOP

Indicates an emergency stop error.

RMD

DONE

Indicates an arc error.

 

OVER

 

 

REL

 

 

 

 

 

 

 

 

 

 

 

 

 

AVER

 

 

TRIG

 

 

 

 

 

 

Indicates an over

Indicates a trigger

average current error.

closed error.

ERR

UNKN

Indicates an unknown error.

WELD WAIT

The weld wait error indicates unit was not ready for a weld sequence. Press Jog/ Purge button to clear error.

MOTR COM

The motor communication error indi- cates motor board lost data communica- tions. Press Jog/Purge button to clear error.

PLS WAIT

The uim communication error indicates user interface board lost data communications. Press Jog/Purge button to clear error.

OVER CRNT

The over current error indicates welding power source primary current is too high. Check and correct input power. Press Jog/ Purge button to clear error.

LOW WFS

The low wire feed speed error indicates actual wire feed speed is lower than wire feed speed command. Check for obstructions in the wire feed system or a faulty wire drive system. Press Jog/Purge button to clear error.

E STOP

The emergency stop error occurs if the user presses an emergency stop button. Reset the emergency stop button and press Jog/Purge button to clear error.

RMD DONE

The RMD done error indicates the RMD demo is completed. Press Jog/Purge button to clear error.

OVER AVER

The over average error indicates that cur- rent is outside the average range for the set program parameters. Check and correct program parameters. Press Jog/Purge but- ton to clear error.

REL TRIG

The release trigger error indicates the user held the trigger when starting a weld program Press Jog/Purge button to clear error.

ERR UNKN

The unknown error indicates a malfunc- tion in the system somewhere. Press Jog/ Purge button to clear error.

OM-217 834 Page 26

Image 30
Contents Description OM-217 834GProcesses File Advanced Manufacturing SystemsFrom Miller to You Table of Contents Page Arc Welding Hazards Symbol UsageMarks a special safety message Electric Shock can killFlying Metal can injure eyes ARC Rays can burn eyes and skinWelding can cause fire or explosion Buildup of GAS can injure or killCalifornia Proposition 65 Warnings Principal Safety Standards EMF InformationAbout Pacemakers UNE Décharge Électrique peut entraîner la mort LES Fumées ET LES GAZ peuvent être dangereuxIndique un message de sécurité particulier DES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer unIncendie ou une explosion DES Pièces Chaudes peuvent provoquer des brûlures graves’EMPLOI Excessif peut SUR Risque D’INCENDIE OU D’EXPLOLA Chute DE L’APPAREIL peut blesser DES Organes Mobiles peuvent provoquer des blessuresPrincipales normes de sécurité En ce qui concerne les stimulateurs cardiaques− Introduction − InstallationSpecifications Mounting Plate Hole LayoutInstalling Insulator Kit Turn Off and disconnect input powerRemote Operator Interface And Wire Drive Installation Connection DiagramGun Recommendation Table Rear Panel ConnectionsPin Network Receptacle Information Pin InformationPower Source Display At Power Up Dual Schedule Switch OptionPower Source Upper Display Lower Display Voltage Range − Operation Operational TermsPower Switch See See Section Program Volts Time Arc AdjustFront Panel Sections SectionVolts Arc Adjust Program Push ButtonUpper Display Lower Display Feeder Set Up Push Button Adjust KnobSequence Trigger Control Trigger Hold Feeder Set Up Process Set Up Push Button CO2Jog/Purge switch provides the following functions Jog/PurgeReset Mode RST− Setting Sequence Parameters Sequence Parameters In a ProgramSequence Parameters Disconnect power − MaintenanceRoutine Maintenance Before maintainingDiagnostics ERR ARCClosed error Indicates a triggerOM-217 834 − Electrical Diagram Circuit Diagram214 842-E − Parts List Remote Operator InterfacePC1 Page Page Page Service SupportOwner’s Record Miller Electric Mfg. Co