Multi-Tech Systems MT2834ZDX manual FCC CFR47 Part 68 Telecom

Page 25

Appendix A – Regulatory Compliance

FCC CFR47 Part 68 Telecom

1.This equipment complies with Part 68 of the 47 CFR rules and the requirements adopted by the ACTA. Located on this equipment is a label that contains, among other information, the registration number and ringer equivalence number (REN) for this equipment or a product identifier in the format:

For current products is US:AAAEQ##Txxxx. For legacy products is AU7USA-xxxxx-xx-x.

If requested, this number must be provided to the telephone company.

2.A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable 47 CFR Part 68 rules and requirements adopted by the ACTA. It’s designed to be connected to a compatible modular jack that is also compliant.

3.The ringer equivalence number (REN) is used to determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact the local telephone company. For products approved after July 23, 2001, the REN for this product is part of the product identifier that has the format US:AAAEQ##Txxxx. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label.

4.If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.

5.The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.

6.If trouble is experienced with this equipment, please contact Multi-Tech Systems, Inc. at the address shown below for details of how to have the repairs made. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved.

7.Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.

8.No repairs are to be made by you. Repairs are to be made only by Multi-Tech Systems or its licensees. Unauthorized repairs void registration and warranty.

9.If your home has specially wired alarm equipment connected to the telephone line, ensure the installation of this equipment does not disable your alarm equipment.

If you have questions about what will disable alarm equipment, consult your telephone company or a qualified installer.

10.Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.

11.This equipment is hearing aid compatible.

12.Manufacturing Information:

Manufacturer: Multi-Tech Systems, Inc.

Model Number: MT2834ZDX, MT2834ZDXb

FCC Registration Number: AU7USA-20673-MM-E

Ringer Equivalence Number: 0.3B

Modular Jack (USOC): RJ11C or RJ11W (single line)

Service Center in USA: Multi-Tech Systems, Inc. 2205 Woodale Drive Mounds View, MN 55112

(763)785-3500

(763)785-9874 Fax

Multi-Tech Systems, Inc. MT2834ZDX User's Guide

25

Image 25
Contents MT2834ZDX-Series External Data/Fax Modem Users Guide User Guide MT2834ZDX-Series S000309C Rev. C Contents Safety Warnings Introduction InstallationFeatures Getting StartedAttach the Self-Adhesive Feet Modem InstallationConnect the Modem to Your System Install Data Communications Software Install the Modem DriverRemoving Your Old Modem from Windows Operation Speed Indicator Blink RatesFront Panel AT Commands AT Commands, S- Registers and Result CodesDCn AT Command Control $BAn Baud AdjustCarrier Detect Control CDn Cleardown at DisconnectEn V.42 Error Correction Modes En Echo Command Mode CharactersEn Non-Error Correction Mode Flow Control DPn Read Line Probe DataLoad Default Configurations $En V.42 Error Correction at 300 bps$Fn Enable/Disable Auto-Reliable Fallback Character Fn Echo Frequency Canceller Offset Compensation#L n V.42 Mode Selection in Originate Mode List Commands$H n Help Screens Inquire Product Codes$MBn Modem Baud Rate Result Codes Enable/DisableNd Dial a Stored Number NdNe. .. Number LinkingRAn Asymmetrical Bit Rate Rn Clear to Send ControlRDn Square Wave Ring Detect RFn CTS/RTS Interaction ControlSFn DSR/CD Interaction Control Tn Respond to Remote Digital Loopback Signal$SBn Serial Port Baud Rate Tone-DialModem Reset Wn Store ConfigurationReturn to Command Mode Xn Result Codes and Call Progress Selection+++ATCR Escape Code Atcr Remote Configuration Escape SequenceBreakatcr Escape Sequence Registers Register Unit Range Default DescriptionTerse Verbose Result CodesNone of the LEDs Light When the Modem Is On TroubleshootingModem Dials But Cannot Connect Modem Disconnects While Online There Are Garbage Characters on the Monitor Regulatory Compliance Appendix a Regulatory ComplianceFCC CFR47 Part 15 Regulation FCC CFR47 Part 68 Telecom USAAAEQ##Txxxx Current Requirements for Label Content and FormatRegulatory Requirements for Canada IC XXXXXX-ZZZZZZZZ Where Industry CanadaCommand Buffer 60 characters Appendix B Technical SpecificationsManual Control Power switch Transmit Level -13 dBm Frequency Stability +/-0.01%Multi-Tech Warranty Statement Appendix C Warranty and ServiceRepair Procedures for U.S. and Canadian Customers Replacement Parts Repair Procedures for International DistributorsOnline Warranty Registration About the Internet July Index AT CommandsNone of the LEDs light when the modem is on