Multi-Tech Systems 40-01459-D0-001 manual Mainframe Configuration, OS/390 Device Definition

Page 44

Mainframe Configuration

This section discusses configuration of the mainframe for use with TCP/IP Direct Connect over a Channel-to-Channel (CTC) link. Mainframe configuration for Communications Server, SNA Server, TCP/IP Passthrough for Windows NT, and MPC+ for Windows is discussed in the user’s guide that accompanied each individual product.

OS/390 Device Definition

As discussed in the previous section, TCP/IP Direct Connect over CTC uses two adjacent sub-channel addresses.

The two sub-channel addresses must both be defined to the mainframe as Serial Channel-to-Channel (SCTC) devices.

OS/390 Version 2 Release 4 and above uses the HCD Configuration Utility, a menu- based interactive program to complete this task. Refer to the OS/390 HCD User’s Guide for instructions on using HCD.

Make sure the Subchannel Address field on the TCP/IP Direct Connect Properties screen points to the device address in the ESCON Configuration for a SCTC device that has been defined in HCD (see Figure 5-23).

OS/390 Parmlib Update

You must turn off the missing interrupt handling processes in OS/390 for the device addresses being used for TCP/IP Direct Connect. To do this add the following statement to the SYS1.PARMLIB(IECIOSxx) member:

MIH TIME=00:00,DEV=(xxx-yyy)

where xxx-yyy defines the range of devices being used by TCP/IP Direct Connect.

38 PCI ESCON Adapter Installation Guide

Image 44
Contents Installation Guide PCI Escon AdapterCopyright 2001 by BUS-TECH, INC Bus-Tech PCI Escon Installation GuideFederal Communications Commission FCC Statement Table of Contents∙ ∙ ∙ ∙ Page Who Should Use This Publication How to Use This PublicationWhat is Included in This Publication What’s New in this Release? Introduction Server SoftwareRelated Documentation Document Number TitleMinimum System Requirements HardwareSoftware Windows OS/390Page Installing the Adapter StepPCI Escon Adapter Installation Guide Driver Installation WindowsSearch the Floppy New Found Hardware Wizard Completing Windows NT Network Icon on Control PanelNetwork Screen Insert Disk screen is displayed Figure 10. Escon Configuration Page Escon Configuration OverviewPCI Escon Adapter Installation Guide Channel Link Address Configuration Accessing Escon Configuration in WindowsSelect the Adapters tab Figure To configure a new device click Add… Adapter Properties with New Devices Page TCP/IP Direct Connect Installation StepClick OK when Setup displays it’s Welcome dialog Figure New Local Connection TCP/IP Properties Deleting a Link 10. Removing a Link11. Invoking Network Configuration 12. Adapter List with Escon Adapter 14.Insert Disk 16. Adapter Properties 18. Adapter Bindings 20. Select TCP/IP Direct Connect 21. Assigning an IP Address to the Escon Adapter Link Configuration 22. CTC Link PropertiesPage OS/390 Device Definition Mainframe ConfigurationOS/390 Parmlib Update TCP/IP Profile GatewayIocds Lpar Sample Configuration TCP/IP RoutingSubnet 207.168.12.1 207.168.12.65 26. TCP/IP Direct Connect Configuration Screens Updating Workstation Configurations 27. Simple Network with No Gateways28. Windows 95 TCP/IP Properties Page Hardware Color \ LED Top LED Bottom LEDYellow RedStep Escon Configuration Displaying Adapter PropertiesHighlight the Escon adapter and click Properties TCP/IP Direct Connect Windows 2000 ConsoleMainframe TCP/IP Profile Problem Solving Preparing for the CallPlacing the Call Additional Technical Support ResourcesCustomer Response BUS-TECH, INC Middlesex Turnpike BURLINGTON, MAPage Connectors Physical AttributesStandards Software