In most existing networks today it will not be necessary to update the TCP/IP configuration on a workstation in order to allow it to connect to the mainframe using an ESCON adapter and TCP/IP Direct Connect. Most workstations already point to an existing router and/or server as a default gateway and that will be all that is needed.

The one notable exception to that rule is a single segment LAN with no gateways(Figure 5-27).

Figure 5-27. Simple Network with No Gateways.

In this situation it will be necessary to modify the TCP/IP Properties for all workstations requiring access to the mainframe through TCP/IP Direct Connect.

Assuming the token-ring adapter in the server in Figure 5-27 is configured with an IP address of 207.168.12.68, Figure 5-28 shows a sample Windows 95 TCP/IP Properties configuration to access the mainframe through the gateway.

44 PCI ESCON Adapter Installation Guide

Image 50
Contents Installation Guide PCI Escon AdapterCopyright 2001 by BUS-TECH, INC Bus-Tech PCI Escon Installation GuideFederal Communications Commission FCC Statement Table of Contents∙ ∙ ∙ ∙ Page Who Should Use This Publication How to Use This PublicationWhat is Included in This Publication What’s New in this Release? Introduction Server SoftwareRelated Documentation Document Number TitleSoftware Windows Minimum System RequirementsHardware OS/390Page Installing the Adapter StepPCI Escon Adapter Installation Guide Driver Installation WindowsSearch the Floppy New Found Hardware Wizard Completing Windows NT Network Icon on Control PanelNetwork Screen Insert Disk screen is displayed Figure 10. Escon Configuration Page Escon Configuration OverviewPCI Escon Adapter Installation Guide Channel Link Address Configuration Accessing Escon Configuration in WindowsSelect the Adapters tab Figure To configure a new device click Add… Adapter Properties with New Devices Page TCP/IP Direct Connect Installation StepClick OK when Setup displays it’s Welcome dialog Figure New Local Connection TCP/IP Properties Deleting a Link 10. Removing a Link11. Invoking Network Configuration 12. Adapter List with Escon Adapter 14.Insert Disk 16. Adapter Properties 18. Adapter Bindings 20. Select TCP/IP Direct Connect 21. Assigning an IP Address to the Escon Adapter Link Configuration 22. CTC Link PropertiesPage OS/390 Device Definition Mainframe ConfigurationOS/390 Parmlib Update TCP/IP Profile GatewayIocds Lpar Sample Configuration TCP/IP RoutingSubnet 207.168.12.1 207.168.12.65 26. TCP/IP Direct Connect Configuration Screens Updating Workstation Configurations 27. Simple Network with No Gateways28. Windows 95 TCP/IP Properties Page Yellow HardwareColor \ LED Top LED Bottom LED RedStep Escon Configuration Displaying Adapter PropertiesHighlight the Escon adapter and click Properties TCP/IP Direct Connect Windows 2000 ConsoleMainframe TCP/IP Profile Problem Solving Preparing for the CallPlacing the Call Additional Technical Support ResourcesCustomer Response BUS-TECH, INC Middlesex Turnpike BURLINGTON, MAPage Standards ConnectorsPhysical Attributes Software