Appendix E – Connecting to a Cisco Router

Appendix E – Connecting to a Cisco Router

Connecting to a Cisco Router Console Port

The console port on the Cisco IOS® router is an asynchronous serial port configured as data communications equipment (DCE). For Cisco 1000, 1600, 2500, 2600, and 3600 series routers, the console port uses an RJ-45 connector.

WARNING: Do not connect the modem to the Cisco router’s auxiliary port. This procedure and document apply only to the Cisco router’s console port.

Step 1: Configure the Modem for your Country or Region

Configure the modem defaults to match the requirements of the country/region in which it will be used. For information on how to do this, see “Step 5: Configure the Modem for your Country or Region” in Chapter 2.

Step 2: Configure for Callback Security in Direct Connect Mode

Callback security requires a caller to give a correct password before sending data to the system. If you do not plan to use this feature, skip to Step 3. Note: Setting the modem for callback security in direct connect mode disables the remote configuration feature of the modem.

To Turn Direct Connect Callback Security On and Off

Callback security must be turned on to enter many callback security commands.

Using a terminal program such as HyperTerminal, type the command AT#Sxxxxxxxx, where xxxxxxxx is

your password (1 to 8 characters long). Press ENTER. The modem responds with OK if the setup password is correct and ERROR if it is wrong. The default password is MTSMODEM. If you wish to change the password, then type the command AT#S=xxxxxxxx, where xxxxxxxx is the new password (1 to 8 characters long), and press ENTER.

Type one of the following commands:

To turn on remote callback security only, type AT#CBS2 and press ENTER.

To turn on both local and remote callback security, type AT#CBS1 and press ENTER. When local

security is turned on, you must enter the setup password before you can enter any AT command from

alocal terminal except the AT, ATIn, and AT#Sxxxxxxxx commands. Type AT&W0 to store the above commands to nonvolatile memory.

To Set the Parity of the Callback Security Messages

The modem’s password prompt and messages parity must match the parity of the computer to which the modem is connected.

1.The default parity setting for your modem is no parity (AT#CBP0). To change the modem’s prompt messages to use even parity, type AT#CBP2 and press ENTER. For odd parity, type AT#CBP1 and press ENTER.

2.To store the new parity value, type AT&W and press ENTER.

To Assign Callback Passwords

To store a callback password for the first callback memory location, type AT#CBN0=xxxxxxxx, where

xxxxxxxxis the first password. Press ENTER. The password must be unique, must be 6 to 10 characters in length, and must not contain a + or - character.

To store a callback password for the second callback memory location, type AT#CBN1=xxxxxxxx, where

xxxxxxxxis the second password, and press ENTER. Note that the memory location number in the command is incremented by one.

Repeat as many times as necessary until all passwords have been entered.

To review your entries, type AT&V and press ENTER.

To set the modem for direct connect mode, type AT%H1 and press ENTER.

To Call a Modem Configured for Callback Security

1.Using a terminal program and an originating modem, dial the number of the modem connected to the Cisco router, which we will call the “remote modem.”

2.When connection is established, the remote modem responds: Password>

3.Type a direct connection password, and press ENTER. You have three attempts or one minute to enter a valid password.

4.If the password is valid, the message OK Connecting appears and the modems establish a working connection.

Multi-Tech Systems, Inc. MT9234ZBA-Series User Guide (S000387C)

33

Image 33
Contents MultiModem ZBA Trademarks PN S000387C, Version C CopyrightPatents World HeadquartersContents Features AT Commands InfoIntroduction CE Mark Technical SpecificationsSafety Warnings InstallationChange the Internal Jumpers Opening the ModemChanging the Voice Jumper Connect the Modem to Your PC Power-On Test Connect the Modem to the AC Power OutletInstall the Modem Driver Windows InstallerPage Using the Global Wizard to Configure Your Modem Configure the Modem for Your Country or RegionUsing AT Commands to Configure Your Modem Click Initial Setup and Country/Region SelectionConnecting to the Internet SetupOperation About the Front PanelRemote Configuration Changing the Setup PasswordChanging the Remote Escape Character Changing the Setup Password Callback SecurityTurning Callback Security On and Off Assigning Callback Passwords and Phone Numbers Setting Callback Security Message ParityCalling Procedures Password-Only CallbackNumber-Entry Callback Direct Connection Extension-Entry CallbackCallback Assignments Form Callback Security CommandsTroubleshooting None of the Indicators LightModem Does Not Respond to Commands Modem Cannot Connect When Dialing Page There Are Garbage Characters on the Monitor Data Is Being LostModem Doesn’t Work with Caller ID Fax and Data Software Can’t Run at the Same TimeAppendix a Upgrading the Modem’s Firmware Download the Upgrade FileIdentify the Modem Firmware Identify the Current Firmware VersionUpgrade the Modem’s Firmware Extract the Upgrade FilesRestore Your Parameters Clear Your Stored ParametersAppendix B Regulatory Compliance FCC Part 15 RegulationFCC Part 68 Telecom Canadian Limitations Notice EMC, Safety and R&TTE Directive ComplianceIndustry Canada Thailand ApprovalNew Zealand Telecom Warning Notice South African StatementJapan Requirements Special phone cable is required for regulatory compliance Brazil Special Cable for MT9234ZBA model onlyAppendix C Environmental Information Weee Waste Electrical and Electronic Equipment StatementReach Statement Appendix C Environmental Info CR6+ Rohs HT/TS Substance ConcentrationAppendix D Installing a Modem under Linux Appendix E Connecting to a Cisco Router Configure the Modem for your Country or RegionConfigure for Callback Security in Direct Connect Mode Console Port Final Setup Remote ConfigurationConsole Port Connections Index AT commands
Related manuals
Manual 38 pages 57.14 Kb Manual 35 pages 61.01 Kb

MT9234ZBA-V, MT9234ZBA specifications

Multi-Tech Systems has long been a trusted name in the field of communication technology, and its MT9234ZBA and MT9234ZBA-V modem products exemplify the company's commitment to delivering robust and reliable connectivity solutions. These modems are ideal for a range of applications, including telephony, data communication, and remote monitoring, making them a versatile choice for both personal and professional use.

One of the standout features of the MT9234ZBA and MT9234ZBA-V is their high-speed data transmission capabilities. Both models support data rates of up to 56 Kbps, ensuring efficient and swift data transfer for various applications. This allows users to experience minimal latency during downloads and uploads, appealing to those who depend on timely and reliable data delivery.

These modems utilize advanced technologies, such as V.92 and V.90 protocols, which enable users to benefit from features like quick connect, thereby reducing the time it takes to establish a connection. Additionally, the modems support both analog and digital lines, making them adaptable for different environments and infrastructures.

Another notable characteristic of the MT9234ZBA and MT9234ZBA-V modems is their compatibility with a wide range of operating systems, including various versions of Windows, Linux, and Mac OS. This cross-platform support ensures that users can easily integrate these modems into their existing software environments without encountering significant compatibility issues.

The design and construction of these modems are also worth mentioning. They are compact and lightweight, making them easy to install and reposition as needed. Their robust construction ensures longevity, which is crucial for users in environments where durability is paramount.

For those concerned about security, Multi-Tech Systems has integrated multiple security features within these modems. This includes support for encryption protocols, ensuring that data transmitted over the modem remains secure and protected from unauthorized access.

In conclusion, the MT9234ZBA and MT9234ZBA-V by Multi-Tech Systems represent an excellent choice for anyone in need of reliable and high-speed modem solutions. With their advanced features, compatibility with various operating systems, and emphasis on security, these modems stand out in the crowded telecommunications market. Whether for home use or in a professional setting, the MT9234ZBA and MT9234ZBA-V offer robust solutions for modern communication needs.