Murphy LS200NDVOR manual LS200 & L1100 Series Liquid Level Switches

Page 1

0600009

09-23-08 Catalog Section 15

LS200 & L1100 Series Liquid Level Switches

LS200 Liquid Level Switches with 2” NPT mounting are float activated to operate an electrical SPDT snap switch (optional DPDT on some models) for alarm or shutdown of an engine or electric motor. The LS200 connects directly into the vessel wall and can be used with a Murphy weld collar (P/N 15050375) or Murphy external float chamber (P/N 15700799). L1100 models (1-1/2” NPT) are also available.

LS200NDVOR is a float-activated, pneumatic-vent level device used to operate dump valves or similar devices.

The LS200NDVOR provides a 2” NPT mounting with a pneumatic output for interfacing with pneumatic devices such as our Murphy pneumatic dump valve or with other pneumatic instrumentation.

LS200NDVO is the Dump Valve Operator (DVO) without the pressure regulator for those applications where the system

provides a filter regulator for “instrument quality” air or gas as the control medium. LS200N is the pneumatic level switch without the DVO and filter regulator.

NOTE: Pneumatic media devices require clean, dry, instrument quality air or gas. This unit is supplied with a pressure regulator, filter and Murphy 20BPG pressure gage for improved system life and trouble-free operation.

Features

Designed for harsh gas compressor scrubber applications

304 stainless steel float operates in 0.55 specific gravity and heavier fluids (see Table 1)

LS200 series rated for 2000 psi (13.8 MPa) [138 bar] working pressure

Electric and pneumatic models available

More robust design

All models screw directly into the vessel or can be mounted via external float chamber

Nickel plated body to provide enhanced corrosion protection

Listed for Class I, Div. 1, Grp. C & D locations

Canadian Registration Number OF1476.2

Stainless Steel models are available for corrosive atmospheres.

Trip on rising liquid level only

Image 1
Contents LS200 & L1100 Series Liquid Level Switches Product Dimensions AccessoriesExternal Float Chamber Weld CollarApplication Data Electrical How to Order your Level Switch Specifications