CCSCF30xx-10x

 

Part Number

 

 

 

Port One - Copper

 

Port Two - Single Fiber Optic

 

 

 

 

 

 

 

 

SC, 1550 nm (TX)/1310 nm (RX)

 

 

CCSCF3029-101 **

 

 

75 ohm coax (BNC)

 

 

 

 

 

 

 

 

 

single mode, 20 km (12.4 miles)*

 

 

 

 

 

 

 

 

 

 

 

CCSCF3029-102 ***

 

 

75 ohm coax (BNC)

 

SC, 1310 nm (TX)/1550 nm (RX)

 

 

 

 

 

 

 

 

single mode, 40 km (24.8 miles)*

 

 

 

 

 

 

 

 

 

 

 

CCSCF3029-103 ***

 

75 ohm coax (BNC)

 

SC, 1550 nm (TX)/1310 nm (RX)

 

 

 

 

 

 

 

 

single mode, 40 km (24.8 miles)*

 

 

CCSCF3039-100

 

 

75 ohm coax (BNC)

 

LC, 1300 nm multimode, 2 km

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1.2 miles)*

 

 

 

 

 

 

 

 

 

 

 

 

* Typical maximum cable distance. Actual distance is dependent upon the

physical characteristics of the network. (TX) = transmit (RX) = receive

Installation -- Continued

CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting the configuration switches. Failure to observe this caution could result in damage to, and subsequent failure of, the media converter.

Set the Configuration Switches

The configuration switches are located on the media converter circuit board. Use a small, flat-blade screwdriver to set the recessed switches.

**

CCSCF3029-100and -101 are intended to be installed in the same network.

*** CCSCF3029-102and -103 are intended to be installed in the same network.

Installation

CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting the jumpers. Failure to observe this caution could result in damage to, and subsequent failure of, the media converter.

Set the Hardware/Software Jumper (J3)

The hardware/software jumper is located on the circuit board of the media converter. Use a small needle-nose pliers or similar device to move the jumper to the desired position.

Switch 1 -- Select DS3 or E3 up - Supports a DS3 interface. down - Supports a E3 interface.

Switch 2 -- Coax Line Build Out (DS3 only)

up - The DS3 line is set up to operate at distances up to 225 ft. (68.6 m).

1

up

DS3

down

E3

2

up

< 225 ft. (68.6 m)

Hardware The media converter mode is determined by the switch settings.

Software The media converter mode is determined by the most-recently saved, on-board microprocessor settings.

H S

Hardware Mode

H S

Software Mode

down - The DS3 line is set up to operate at distances greater than 225 ft. (68.6 m).

down

> 225 ft. (68.6 m)

Switch 3 -- Signal on Loss of Carrier

3

Set the Coax Grounding Jumpers (J11 & J12) (Optional)

NOTE: Modify the settings for J11 and J12 only if necessary.

Jumpers 11 and 12 (located on the circuit board near the coax ports) provide a grounding feature so that the CCSCF30xx-10x media converter complies with the G.703 specification where:

The output coax port is connected to chassis ground.

A provision to connect the input coax port to chassis ground is provided. The factory settings for these two jumpers are:

Jumper 12 (jumpered)

= Output coax port is connected to chassis ground.

Jumper 11 (not-jumpered) = Input coax port is not connected to chassis ground.

J11

J12

not jumpered

jumpered

up - Transmits an alarm indication signal (AIS) on the loss of the input carrier (unframed).

down - No signal is transmitted on the loss of the input carrier (unframed).

Switch 4 -- Alarm Indication Signal (AIS)

up - AIS is defined as a pattern of alternating 1’s and 0’s (unframed).

down - AIS is defined as a pattern of all 1’s (unframed).

up

Transmit alarm

down

No signal

4

up Alarm = 1's and 0's

down Alarm = all 1's

2

24-hour Technical Support: 1-800-260-1312-- International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

3

Image 2
Contents Slide-in-Module Media Converter Set the Hardware/Software Jumper J3 InstallationSet the Configuration Switches Set the Coax Grounding Jumpers J11 & J12 OptionalInstall the Coax Cable Set the Loop-Back SwitchInstall the Slide-In-Module Install the Fiber CableOperation Cable SpecificationsPower the Media Converter Coax CableTechnical Specifications TroubleshootingCCSCF30xx-10x Is Data Transfer Failing? Is the SDC Signal Detect / Coax LED illuminated yellow?Is the SDF Signal Detect / Fiber LED illuminated yellow? Declaration of ConformityCompliance Information 33215.D