Lucent Technologies Host-Based Controller Modem AT specifications 255

Page 79

Data Addendum

Host-Based Controller Modem

June 15, 1998

AT Command Set

 

 

AT Commands for Homologation Testing and Debugging (continued)

Table 15. The Country Specific Homologation Parameters (continued)

Par. #

Taiwan

Thailand

Indonesia

Ireland

Portugal

Hong Kong

23

1

1

1

1

1

1

24

0

0

0

0

0

0

25

5

5

5

0

5

5

26

50

9

50

7

20

50

27

3

2

2

4

4

2

28

65

10

65

4

4

65

29

35

35

35

10

30

35

2a

65

65

65

39

60

65

2b

2

2

2

4

2

2

2c

65

10

65

8

5

65

2d

1

1

1

1

1

1

2e

255

255

255

255

255

255

2f

10

10

10

9

9

10

30

0

0

0

0

1

0

31

3

3

3

3

3

3

32

0

0

0

0

0

0

33

1

1

1

1

0

1

34

255

255

255

255

255

255

35

1

1

1

1

1

1

36

25

25

25

25

25

25

37

0

0

0

0

0

0

38

2

2

2

3

2

2

39

0

0

0

0

0

0

3a

0

0

0

0

0

0

3b

1

1

1

2

3

1

3c

43

35

43

43

35

43

3d

0

0

0

0

1

0

3e

30

30

30

30

30

30

3f

10

10

10

10

10

10

40

37

37

37

33

37

37

41

50

50

50

39

50

50

42

43

43

43

43

43

43

43

0

0

0

0

0

0

44

43

43

43

43

43

43

45

0

0

0

0

0

0

46

1

1

1

1

1

1

47

0

0

0

1

0

0

48

0

0

0

0

0

0

Version 1.0

Lucent Technologies Inc.

79

Image 79 Contents
Introduction ContentsAT Command Set Summary Description AT Command SummaryS-Register Summary Default Description AT Testing and Debugging Command Set Summary Description#UD Result Code Summary NoEC-No error control protocol AT Commands Reference Online Data Character Echo Command Echo CommandDnDial Request ID Information Otherwise Hook ControlMars Lapm Monitor Speaker Mode Monitor Speaker VolumeModulation Handshake VnDCE Response Format Return On-line to Data ModeSelect Pulse Dialing Result Code ControlExtended Result Codes Result Code OptionResult Code Selection and Call Progress Monitoring Ext. Result Code Dial Tone Detect Busy Tone DetectAuto Retrain OK ErrorLong Space Disconnect Recall Stored ProfileAuxiliary Relay option Fn Load Factory SettingsDn DTR Control Gn V.22bis Guard Tone ControlPulse Dial Make-to-Break Ratio Selection Asynchronous Communications ModeQn Asynchronous Communications Mode Local Flow Control SelectionConnect Error Self-Test CommandsData Set Ready DSR Option SSE View Active Configuration and Stored Profile\An Store Current ConfigurationYnSelect Stored Profile for Hard Reset Zn=x Store Telephone Number\Nn Error Control Mode Selection Bits/s Rate Adjusted\Kn Break Control \N3 Data Calling Tone \Tn Inactivity Timer\Vn Protocol Result Code \Xn XON/XOFF Pass ThroughView Numbers in Blacklist Cn Data Compression Control En Enable/Disable Auto-Retrain and Fallback/Fall ForwardTest and Debug AT Commands AT#UD Last Call Status Report Format DiagGstnModulationSchemeActive from 3.7.2/V.58 Call Setup Result CodesValue Description Implemented ErrorControl Active from 3.5.2/V.58 Value DescriptionCompressionActive from 3.2.2/V.58 Value Description CallCleared codes from 3.6.4/V.58-1994DteHangupCommand AT Escape Character user defined AT Commands Reference S-RegistersS3Command Line Termination Character user defined Auto Answer Ring NumberResponse Formatting Character user defined Command Line Editing Character user definedConnection Completion Time-Out S12 Escape Guard Time Comma Dial Modifier TimeS10 S11S28 S24 Timer to Control Sleep ModeS21 24/General Bit Mapped Options Status S22 Results Bit Mapped Options StatusS35 S30 Inactivity TimerS32 Synthetic Ring Volume S33 Synthetic Ring FrequencyS38 K56flex Downstream Rate S42 Auto Rate default 1, range 0 ¾1S89 S43 Auto Mode default 1, range 0¾1S48 Lapm Error Control and Feature Negotiation default S48 S48 =AT FAX Command Set Summary AT FAX Command Set Class 1 FAXCommand Description AT FAX Commands Reference +FTM=m Transmit FAX Data with m Carrier Command Option Modulation Speed bits/s+FRM=m Receive FAX Data with m Carrier +FRH=m Receive Hdlc Data with m Carrier +FTH=m Transmit Hdlc Data with m CarrierFPR Product Identification +FMM +FAA Adaptive answerManufacturer Identification +FMI Result Lucent Data/FaxAT Voice Command Set Not Defined In IS-101 Specification AT Voice Command SetAT Voice Command Set Voice CommandsAT Voice Commands Reference AT+VNH = Hook Automatic Hang-up Control AT+VIT = Timer DTE/DCE Inactivity TimerAT+VGR=gain AT+VEM=mask Event Reporting and MaskingStart voice transmission and reception process AT+VLS=label Analog Source/Destination SelectionAT+VTD=dur AT+VTS=stringAT+VSM? AT+VSD=sds, sdi Silence Detection Quiet and SilenceAT+VSM=? Events Reported to the DTE AT+VRA=interval Ringback Goes Away TimerAT+VRN=interval Ringback Never Appeared Timer AT+VPR=rate Select DTE/DCE Interface RateAT+VTS= ATD DLE HAT+VLS=5 AT+VLS=7ATH Example # 2 Initiating a stored number speakerphone call ATA Example # 3 Answering a speakerphone callRing AT+FCLASS=1AT+VLS=1 Example # 6 Switching from speakerphone mode to TAD modeAT+FCLASS=0 ConnectDLE-R Modem answers call AT Dsvd Commands Version / Revision Information +GMR? 25ter AT Commands25ter AT Commands Manufacturer Identification +GMI?V8o, v8a, and v8cf +ES? AT Commands+ES=? +ITF=? Idle,,,crctype,nrzien+ESA=? +ITF= off, onAT Commands for Homologation Testing and Debugging Version USA Country Codes CountryCode in HEXAT%T21,par#,paramvalue Pulse dial make time 255 ATH1 ATA, ATDATD , ATX ATBPar # Parameter Description Range Reference Homologation ParametersVersion 150 255 100 120 255 0x00 0x12 0x10 0x88 0x80 0x06 0x0c 0x6b 0xaa Par. # Australia Belgium Denmark Finland France Germany 120 100 255 0x10 0x12 Norway Spain Par. # Netherlands Italy 150 100 250 255 0x12 0x10 0x00 0x88 0x06 0x0c 0x80 Par. # Austria Japan China Korea Malaysia Singapore 150 250 255 Portugal Hong Kong 150 255 Version Par. # Canada Mexico India Vietnam Philippines 000 004 002 050 140 S10 020 S11 095 090 S30 S35 001 000 003 002 004 035 050 S10 020 S11 095 090 S30 S35 001 ATZ OK ATZ OK ATS11? 085 OKXX-XXXDMOD