Table 3-1. Fields in the DSLPipe status window (Continued)

Fields

 

Description

 

 

 

V.35

ch Tx CRC

Shows either Enable or Disable. The default is Enable.

 

 

This means that the CRC is appended to the end of the frame

 

 

when data is sent over the V.35 line.

V.35

ch RxC

Indicates Norm (Normal) or Rev (Reverse). The default is

Polarity

Norm.This means that data will be sampled at the rising edge

 

 

of the clock.

V.35

ch TxC

Indicates Norm (Normal) or Rev (Reverse). The default is

Polarity

Norm.This means that data will be shifted out of the buffer at

 

 

the falling edge of the clock.

 

 

 

Viewing diagnostic information

After you set up the communications software and the DSLPipe unit’s configuration menu appears (see Figure 3-1), you can press 4 to enter debug mode and view diagnostic information. When you press 4, the following window appears:

SDSL V.35 DSU

Debug Mode

0.Return to Main Menu

1.Check HDLC Registers

2.Print Rx Data

Figure 3-2. Debug Mode window

At the Select Function Items prompt, press 1 to display the HDLC registers. Table 3-2 describes the fields that display in the list that appears.

DSLPipe DSU (SDSL) User’s Guide

3-5

Image 25
Contents DSLPipe DSU Sdsl Lucent Technologies Enabling Lucent to assist you Customer ServiceOther telephone numbers Important safety instructions Important safety instructionsImportant safety instructions Special Requirements Important safety instructions Contents Page Introduction DSLPipe DSU configuration DSLPipe DSU featuresDSLPipe DSU architecture DSLPipe DSU architecturePage Checking package contents InstallationPackage contents Setting up the DSLPipe DSUSetting the data transmission rate Checking the activity of the LED lights Connecting the cablesLocation of the LED lights in the DSLPipe DSU front panel Page Items you need Viewing configuration informationBits per second Specify Data bits Specify Viewing configuration information Viewing configuration informationIndicates Norm Normal or Rev Reverse. The default is Debug Mode window Viewing diagnostic informationFields in the Hdlc Registers list Shows Working if the V.35 line is working. Otherwise, shows Page Table A-1. DSLPipe DSU specifications Hardware SpecificationsPage Warranties and FCC Regulations Product warrantyFCC Part 15 Notice Warranty repairIC CS-03 Notice IC CS-03 Notice