Lantronix 900-598 manual To Configure FTP Settings, Syslog Settings Description

Page 62

9:Services Settings

FTP Settings

The FTP protocol can be used to upload and download user files, and upgrade the PremierWave firmware. A configurable option is provided to enable or disable access via this protocol.

 

Table 9-2 FTP Settings

 

 

FTP Settings

Description

 

 

State

Select Enabled or Disabled for the state of the FTP server.

 

 

To Configure FTP Settings

Using Web Manager

To configure FTP, click FTP in the menu bar.

Using the CLI

To enter the FTP command level: enable -> config -> ftp

Using XML

Include in your file: <configgroup name=”ftp server”>

Syslog Settings

The Syslog information shows the current configuration and statistics of the syslog. Here you can configure the syslog host and the severity of the events to log.

Note: The system log is always saved to local storage, but it is not retained through reboots unless diagnostics logging to the filesystem is enabled. Saving the system log to a server that supports remote logging services (see RFC 3164) allows the administrator to save the complete system log history. The default port is 514.

 

Table 9-3 Syslog Settings

 

 

Syslog Settings

Description

 

 

State

Select Enabled or Disabled for the state of the syslog.

 

 

Host

Enter the IP address of the remote server to which system logs are sent for

 

storage.

 

 

Remote Port

Enter the number of the port on the remote server that supports logging services.

 

The default is 514.

 

 

Severity Log Level

Specify the minimum level of system message the PremierWave XC should log.

 

This setting applies to all syslog facilities. The drop-down list in the Web Manager

 

is in descending order of severity (e.g., Emergency is more severe than Alert.)

 

 

PremierWave XC User Guide

62

Image 62
Contents XC User Guide Contacts WarrantyCopyright & Trademark DisclaimerRevision History FCC Part 15.21 StatementFCC RF Radiation Exposure Statement Installation of PremierWave XC Table of ContentsUsing This Guide IntroductionNetwork Settings Using DeviceInstallerConfiguration Using Web Manager Line and Tunnel SettingsSecurity Settings Terminal and Host SettingsServices Settings Maintenance and Diagnostics Settings Advanced SettingsUpdating Firmware EventsSecurity in Detail Branding the PremierWave XC 100Troubleshooting 102 Appendix C Compliance 107List of Figures List of TablesList of Tables Summary of Chapters Using This GuidePurpose and Audience Chapter DescriptionAdditional Documentation Document DescriptionApplications Key FeaturesIntroduction Protocol Support Troubleshooting CapabilitiesConfiguration Methods Hardware Address Addresses and Port NumbersProduct Information Label IP AddressProduct Label User-Supplied Items Installation of PremierWave XCPackage Contents Hardware Components PremierWave XC Male DB9 DTE Serial PortsReset Button Back PanelSerial PowerTop Panel Connector Description Side PanelInstalling the PremierWave XC Bottom PanelPremierWave XC Connections 11 PremierWave XC Dimensions Device Detail Summary Using DeviceInstallerAccessing PremierWave XC using DeviceInstaller Current Settings Description Web Port Telnet SupportedTelnet Port Firmware UpgradableConfiguration Using Web Manager Accessing Web ManagerDevice Status Device StatusWeb Manager Page Components Layout of a typical Web Manager page is belowNavigating the Web Manager Web Manager Description SeeQuery Port NetworkProtocol Stack SyslogDdns Settings Network SettingsWAN Connection Settings To Configure WAN Connection SettingsSetting / Field Description Network 1 Interface SettingsTo View or Configure Ddns Settings Network Interface Description SettingsHostname Default GatewayDhcp Client Dhcp Client IDNetwork 1 Ethernet eth0 Description Link Settings Network 1 Link SettingsTo Configure Network 1 Interface Settings To View Network 1 Interface StatusNetwork 2 wwan0 Description SMS Outbound Settings Network 2 SMS Outbound SettingsTo Configure Network 1 Link Settings Network 2 Interface StatusNetwork 2 SMS Inbound Settings To Configure Network 2 SMS Outbound SettingsNetwork 2 wwan0 Description SMS Inbound Settings Network 2 Roam SettingsTo Configure Network 2 SMS Inbound Settings Network 2 wwan0 Description Roam SettingsTo Configure Network 2 GSM/GPRS bands Settings Network 2 GSM/GPRS Bands SettingsTo Configure Network 2 Roam Settings Network 2 wwan0 Description GSM/GPRS SettingsNetwork 2 wwan0 Description SIM Pin Settings Network 2 SIM Pin SettingsTo Configure Network 2 SIM Pin Settings Network 2 wwan0 Description APN Configuration Settings Network 2 APN Configuration SettingsTo Configure Network 2 APN Configuration Settings Enter Access Point Name APNNetwork 2 wwan0 Description Carrier Connection Settings Network 2 Carrier Connection SettingsTo Configure Network 2 Carrier Connection Settings Network 2 SMS Statistics6Network Settings Configuration Line and Tunnel SettingsLine Settings Line Settings DescriptionCommand Mode Line Command Description Mode SettingsSerial String To Configure Line SettingsStatistics To View Line Statistics Echo Serial StringTunnel Serial Description Settings Tunnel SettingsSerial Settings Tunnel Packing Description Mode Settings To Configure Tunnel Serial SettingsPacking Mode Tunnel Accept Mode Description Settings To Configure Tunnel Packing Mode SettingsAccept Mode Local PortTo Configure Tunnel Accept Mode Settings Reconnect Timer Connect ModeTunnel Connect Description Mode Settings Email on To Configure Tunnel Connect Mode SettingsFlush Serial Data ConnectTunnel Disconnect Mode Description Settings Disconnect ModeTo Configure Tunnel Disconnect Mode Settings Tunnel Modem Emulation Description Settings Modem EmulationTo View Tunnel Statistics To Configure Tunnel Modem Emulation SettingsStatistics Terminal on Network Description Line Settings Terminal and Host SettingsTerminal Settings To Configure the Terminal Line Connection Host ConfigurationTo Configure the Terminal Network Connection SSH Username To Configure Host SettingsHost Settings Description Remote AddressTo View or Configure DNS Settings Services SettingsDNS Settings To Configure FTP Settings FTP SettingsSyslog Settings Syslog Settings DescriptionHttp Settings Description Http SettingsTo View or Configure Syslog Settings Enter the Uniform Resource Identifier URI To Configure Http SettingsHttp Authentication Description Settings To Configure Http Authentication Auth TypeRSS Settings Description RSS SettingsTo Configure RSS Settings Certificate Generation Description Settings Security SettingsSSL Settings Certificate and Key GenerationTo Create a New Credential Upload Certificate Description Settings Certificate Upload SettingsTo Configure an Existing SSL Credential New CertificateTo Upload an Authority Certificate Trusted Authorities Description SettingsTrusted Authorities AuthorityFile Display Commands Description Maintenance and Diagnostics SettingsFilesystem Settings File DisplayFile Modification File Modification Description CommandsFile Transfer Settings Description File TransferProtocol Stack Description IP Settings Protocol Stack SettingsTo Configure IP Network Stack Settings To Transfer or Modify Filesystem FilesProtocol Stack Description Icmp Settings To Configure Icmp Network Stack SettingsTo Configure ARP Network Stack Settings MAC AddressProtocol Stack Description Snmp Settings To Configure Smtp Network Stack SettingsTo Configure Snmp Network Stack Settings Query Port To Configure Query Port SettingsQuery Port Settings Description IP Sockets DiagnosticsHardware To View Hardware Information To View the List of IP SocketsTraceroute Diagnostics Description Traceroute SettingsTo Ping a Remote Host To Perform a TracerouteLog To Configure the Diagnostic Log OutputDiagnostics Description Log Settings MemoryRoute ProcessesTo View Process Information To View Route InformationSystem Settings Description System SettingsTo Reboot or Restore Factory Defaults To View, Configure and Send Email Advanced SettingsEmail Settings Email Configuration Description SettingsTo View and Configure Basic CLI Settings Command Line Interface SettingsBasic CLI Settings Command Line Interface Description Configuration SettingsTelnet Settings Description Telnet SettingsTo Configure Telnet Settings To Configure SSH Settings XML SettingsSSH Settings XML Export ConfigurationTo Export Configuration in XML Format XML Export Configuration Description SettingsXML Export Status Settings Description XML Import ConfigurationImport Configuration from External File XML Export StatusTo Import Configuration in XML Format Failover SettingsImport Configuration from the Filesystem Import Configuration from Description Filesystem SettingsTo Configure Failover Settings Failover Settings DescriptionRelay Output Settings Description Relay Output SettingsTo Configure Relay Output Settings Event Overview Event Alert Settings DescriptionEvents Event AlertsTo Configure Main Power Fail Settings To Configure Input 1 SettingsTo Configure Input 2 Settings To Configure Backup Power Fail Settings To Configure Wwan0 Link Down SettingsTo Clear Events To Configure Ethernet Link Down SettingsEvents Status and Clearing Events Digital Certificates Security in DetailPublic Key Infrastructure Trusted AuthoritiesCertificate Formats Obtaining CertificatesSelf-Signed Certificates OpenSSLSteel Belted Radius Free RadiusLoading New Firmware through Web Manager Updating FirmwareObtaining Firmware To upload new firmwareLoading New Firmware through FTP Short and Long Name Customization Branding the PremierWave XCWeb Manager Customization Name Settings Description To Customize Short or Long NamesProblems and Error Messages TroubleshootingDiagnostic LED States Problem/Message Reason SolutionTroubleshooting Appendix a Technical Support Technical Support USScientific Calculator Appendix B Binary to Hexadecimal ConversionsConverting Binary to Hexadecimal Conversion TableAppendix B Binary to Hexadecimal Conversions Appendix C Compliance Product Name ModelDevice Label with CE Mark and FCC ID Manufacturers ContactRoHS Notice SLB SLC SLP

900-598 specifications

The Lantronix 900-598 is a powerful and versatile device designed to facilitate robust data communication and management for industrial and commercial applications. At the heart of the 900-598 lies its advanced networking capabilities, making it an essential tool for IoT implementations, operational efficiency, and remote device management.

One of the main features of the Lantronix 900-598 is its ability to provide secure and reliable connectivity. The device supports various communication protocols, including serial and Ethernet, enabling seamless integration with a wide array of devices across diverse environments. This flexibility allows users to connect legacy equipment to modern networks, thereby extending the life of existing technologies while enhancing operational capabilities.

The Lantronix 900-598 is equipped with robust security measures to protect sensitive data during transmission. It supports encryption protocols, such as SSL and SSH, ensuring that data remains confidential and secure from unauthorized access. This security is crucial for industries dealing with sensitive information, such as healthcare, finance, and manufacturing, where data breaches can have severe repercussions.

Another notable characteristic of the 900-598 is its ease of use. The device features a user-friendly interface that simplifies setup and configuration. Additionally, it supports remote access and management, allowing users to monitor and control devices from virtually anywhere. This remote management capability is particularly advantageous for organizations with distributed operations, enabling them to maintain oversight without needing to be physically present at each location.

In terms of performance, the Lantronix 900-598 offers high-speed data transfer rates, which are essential for real-time applications. It is designed to handle large volumes of data efficiently, making it suitable for applications that require quick responses and minimal latency. The device ensures reliable operation through features like error correction and data integrity monitoring.

Lastly, the Lantronix 900-598 is built to withstand challenging environmental conditions, thanks to its rugged design. This durability makes it suitable for deployment in harsh industrial settings, where exposure to dust, moisture, and extreme temperatures is common.

In conclusion, the Lantronix 900-598 stands out as an advanced solution for data communication and device management. Its combination of secure connectivity, ease of use, high performance, and durability makes it an excellent choice for businesses looking to modernize their operations and embrace the future of IoT and remote management. With its extensive features and robust technologies, the 900-598 is poised to enhance productivity and streamline processes across various industries.