Lantronix 900-598 manual To Configure Relay Output Settings, Relay Output Settings Description

Page 90

12: Advanced Settings

Relay Output Settings

The PremierWave XC allows Relay Output state to be controlled by events, user commands and SMS inbound messaging.

Configuration of the Relay Output settings allow you to configure the initial state for the Relay Output after boot up, test the Open and Close state of the relay, and configure the SMS inbound message to control the Open and Close state of the Relay output.

 

Table 12-9 Relay Output Settings

 

 

Relay Output Settings

Description

 

 

Initial State

Select Initial State of the relay output to be opened or closed.

 

 

State Preservation

Select to enable or disable preserving the relay output state after warm

 

boot.

 

 

SMS Open CMD

Customize: SMS text controls the relay output to be in open state.

 

 

SMS Close CMD

Customize: SMS text controls the relay output to be in close state.

 

 

To Configure Relay Output Settings

Using Web Manager

To configure Relay Output settings, click Relay Output on the menu bar.

Using the CLI

To enter the XML command level: enable -> relay output

Using XML

Include in your file: <configgroup name=”relay output”>

PremierWave XC User Guide

90

Image 90
Contents XC User Guide Contacts WarrantyCopyright & Trademark DisclaimerFCC Part 15.21 Statement FCC RF Radiation Exposure StatementRevision History Installation of PremierWave XC Table of ContentsUsing This Guide IntroductionNetwork Settings Using DeviceInstallerConfiguration Using Web Manager Line and Tunnel SettingsTerminal and Host Settings Services SettingsSecurity Settings Maintenance and Diagnostics Settings Advanced SettingsUpdating Firmware EventsSecurity in Detail Branding the PremierWave XC 100Troubleshooting 102 Appendix C Compliance 107List of Figures List of TablesList of Tables Summary of Chapters Using This GuidePurpose and Audience Chapter DescriptionAdditional Documentation Document DescriptionKey Features IntroductionApplications Troubleshooting Capabilities Configuration MethodsProtocol Support Hardware Address Addresses and Port NumbersProduct Information Label IP AddressProduct Label Installation of PremierWave XC Package ContentsUser-Supplied Items Hardware Components PremierWave XC Male DB9 DTE Serial PortsReset Button Back PanelPower Top PanelSerial Connector Description Side PanelInstalling the PremierWave XC Bottom PanelPremierWave XC Connections 11 PremierWave XC Dimensions Using DeviceInstaller Accessing PremierWave XC using DeviceInstallerDevice Detail Summary Current Settings Description Web Port Telnet SupportedTelnet Port Firmware UpgradableConfiguration Using Web Manager Accessing Web ManagerDevice Status Device StatusWeb Manager Page Components Layout of a typical Web Manager page is belowNavigating the Web Manager Web Manager Description SeeQuery Port NetworkProtocol Stack SyslogDdns Settings Network SettingsWAN Connection Settings To Configure WAN Connection SettingsSetting / Field Description Network 1 Interface SettingsTo View or Configure Ddns Settings Network Interface Description SettingsHostname Default GatewayDhcp Client Dhcp Client IDNetwork 1 Ethernet eth0 Description Link Settings Network 1 Link SettingsTo Configure Network 1 Interface Settings To View Network 1 Interface StatusNetwork 2 wwan0 Description SMS Outbound Settings Network 2 SMS Outbound SettingsTo Configure Network 1 Link Settings Network 2 Interface StatusNetwork 2 SMS Inbound Settings To Configure Network 2 SMS Outbound SettingsNetwork 2 wwan0 Description SMS Inbound Settings Network 2 Roam SettingsTo Configure Network 2 SMS Inbound Settings Network 2 wwan0 Description Roam SettingsTo Configure Network 2 GSM/GPRS bands Settings Network 2 GSM/GPRS Bands SettingsTo Configure Network 2 Roam Settings Network 2 wwan0 Description GSM/GPRS SettingsNetwork 2 SIM Pin Settings To Configure Network 2 SIM Pin SettingsNetwork 2 wwan0 Description SIM Pin Settings Network 2 wwan0 Description APN Configuration Settings Network 2 APN Configuration SettingsTo Configure Network 2 APN Configuration Settings Enter Access Point Name APNNetwork 2 wwan0 Description Carrier Connection Settings Network 2 Carrier Connection SettingsTo Configure Network 2 Carrier Connection Settings Network 2 SMS Statistics6Network Settings Configuration Line and Tunnel SettingsLine Settings Line Settings DescriptionCommand Mode Line Command Description Mode SettingsSerial String To Configure Line SettingsStatistics To View Line Statistics Echo Serial StringTunnel Settings Serial SettingsTunnel Serial Description Settings To Configure Tunnel Serial Settings Packing ModeTunnel Packing Description Mode Settings Tunnel Accept Mode Description Settings To Configure Tunnel Packing Mode SettingsAccept Mode Local PortTo Configure Tunnel Accept Mode Settings Connect Mode Tunnel Connect Description Mode SettingsReconnect Timer Email on To Configure Tunnel Connect Mode SettingsFlush Serial Data ConnectDisconnect Mode To Configure Tunnel Disconnect Mode SettingsTunnel Disconnect Mode Description Settings Tunnel Modem Emulation Description Settings Modem EmulationTo Configure Tunnel Modem Emulation Settings StatisticsTo View Tunnel Statistics Terminal and Host Settings Terminal SettingsTerminal on Network Description Line Settings Host Configuration To Configure the Terminal Network ConnectionTo Configure the Terminal Line Connection SSH Username To Configure Host SettingsHost Settings Description Remote AddressServices Settings DNS SettingsTo View or Configure DNS Settings To Configure FTP Settings FTP SettingsSyslog Settings Syslog Settings DescriptionHttp Settings To View or Configure Syslog SettingsHttp Settings Description To Configure Http Settings Http Authentication Description SettingsEnter the Uniform Resource Identifier URI To Configure Http Authentication Auth TypeRSS Settings To Configure RSS SettingsRSS Settings Description Certificate Generation Description Settings Security SettingsSSL Settings Certificate and Key GenerationTo Create a New Credential Upload Certificate Description Settings Certificate Upload SettingsTo Configure an Existing SSL Credential New CertificateTo Upload an Authority Certificate Trusted Authorities Description SettingsTrusted Authorities AuthorityFile Display Commands Description Maintenance and Diagnostics SettingsFilesystem Settings File DisplayFile Modification File Modification Description CommandsFile Transfer Settings Description File TransferProtocol Stack Description IP Settings Protocol Stack SettingsTo Configure IP Network Stack Settings To Transfer or Modify Filesystem FilesProtocol Stack Description Icmp Settings To Configure Icmp Network Stack SettingsTo Configure ARP Network Stack Settings MAC AddressTo Configure Smtp Network Stack Settings To Configure Snmp Network Stack SettingsProtocol Stack Description Snmp Settings To Configure Query Port Settings Query Port Settings DescriptionQuery Port IP Sockets DiagnosticsHardware To View Hardware Information To View the List of IP SocketsTraceroute Diagnostics Description Traceroute SettingsTo Ping a Remote Host To Perform a TracerouteLog To Configure the Diagnostic Log OutputDiagnostics Description Log Settings MemoryRoute ProcessesTo View Process Information To View Route InformationSystem Settings To Reboot or Restore Factory DefaultsSystem Settings Description To View, Configure and Send Email Advanced SettingsEmail Settings Email Configuration Description SettingsTo View and Configure Basic CLI Settings Command Line Interface SettingsBasic CLI Settings Command Line Interface Description Configuration SettingsTelnet Settings To Configure Telnet SettingsTelnet Settings Description To Configure SSH Settings XML SettingsSSH Settings XML Export ConfigurationTo Export Configuration in XML Format XML Export Configuration Description SettingsXML Export Status Settings Description XML Import ConfigurationImport Configuration from External File XML Export StatusTo Import Configuration in XML Format Failover SettingsImport Configuration from the Filesystem Import Configuration from Description Filesystem SettingsTo Configure Failover Settings Failover Settings DescriptionRelay Output Settings To Configure Relay Output SettingsRelay Output Settings Description Event Overview Event Alert Settings DescriptionEvents Event AlertsTo Configure Input 1 Settings To Configure Input 2 SettingsTo Configure Main Power Fail Settings To Configure Backup Power Fail Settings To Configure Wwan0 Link Down SettingsTo Configure Ethernet Link Down Settings Events Status and Clearing EventsTo Clear Events Digital Certificates Security in DetailPublic Key Infrastructure Trusted AuthoritiesCertificate Formats Obtaining CertificatesSelf-Signed Certificates OpenSSLSteel Belted Radius Free RadiusLoading New Firmware through Web Manager Updating FirmwareObtaining Firmware To upload new firmwareLoading New Firmware through FTP Branding the PremierWave XC Web Manager CustomizationShort and Long Name Customization Name Settings Description To Customize Short or Long NamesProblems and Error Messages TroubleshootingDiagnostic LED States Problem/Message Reason SolutionTroubleshooting Appendix a Technical Support Technical Support USScientific Calculator Appendix B Binary to Hexadecimal ConversionsConverting Binary to Hexadecimal Conversion TableAppendix B Binary to Hexadecimal Conversions Appendix C Compliance Product Name ModelDevice Label with CE Mark and FCC ID Manufacturers ContactRoHS Notice SLB SLC SLP

900-598 specifications

The Lantronix 900-598 is a powerful and versatile device designed to facilitate robust data communication and management for industrial and commercial applications. At the heart of the 900-598 lies its advanced networking capabilities, making it an essential tool for IoT implementations, operational efficiency, and remote device management.

One of the main features of the Lantronix 900-598 is its ability to provide secure and reliable connectivity. The device supports various communication protocols, including serial and Ethernet, enabling seamless integration with a wide array of devices across diverse environments. This flexibility allows users to connect legacy equipment to modern networks, thereby extending the life of existing technologies while enhancing operational capabilities.

The Lantronix 900-598 is equipped with robust security measures to protect sensitive data during transmission. It supports encryption protocols, such as SSL and SSH, ensuring that data remains confidential and secure from unauthorized access. This security is crucial for industries dealing with sensitive information, such as healthcare, finance, and manufacturing, where data breaches can have severe repercussions.

Another notable characteristic of the 900-598 is its ease of use. The device features a user-friendly interface that simplifies setup and configuration. Additionally, it supports remote access and management, allowing users to monitor and control devices from virtually anywhere. This remote management capability is particularly advantageous for organizations with distributed operations, enabling them to maintain oversight without needing to be physically present at each location.

In terms of performance, the Lantronix 900-598 offers high-speed data transfer rates, which are essential for real-time applications. It is designed to handle large volumes of data efficiently, making it suitable for applications that require quick responses and minimal latency. The device ensures reliable operation through features like error correction and data integrity monitoring.

Lastly, the Lantronix 900-598 is built to withstand challenging environmental conditions, thanks to its rugged design. This durability makes it suitable for deployment in harsh industrial settings, where exposure to dust, moisture, and extreme temperatures is common.

In conclusion, the Lantronix 900-598 stands out as an advanced solution for data communication and device management. Its combination of secure connectivity, ease of use, high performance, and durability makes it an excellent choice for businesses looking to modernize their operations and embrace the future of IoT and remote management. With its extensive features and robust technologies, the 900-598 is poised to enhance productivity and streamline processes across various industries.