Installation Instructions
Each IE-iMcV-E1-Mux/4 module requires two adjacent slots in an iMediaChassis or MediaChassis. To install the module in a chassis, remove the blank faceplates covering the slots where the module is to be installed. Then slide the module into the chassis card guides until the module is seated securely in the slots. Secure the module to the chassis by tightening the captive screw.
All IE-iMcV-E1-Mux/4 units are shipped from the factory configured as Host units. The IE-iMcV-E1-Mux/4 modules must be installed in pairs. For two IE-iMcV-E1- Mux/4 units to properly operate together one unit needs to be configured as a Remote. Configuration as a Host or Remote is controlled via a DIP switch setting (S1- 1).
Small Form-Factor Pluggable Ports (SFP)
The fiber link on the IE-iMcV-E1-Mux/4 module is supported through one or two SFPs (depending on the model) running at 155Mbps. Many SFPs, including those from IMC Networks, feature enhanced diagnostics capabilities DDMI (Data and Diagnostic Management Information). DDMI statistics provide real-time access to transceiver operating parameters such as voltage, temperature, laser bias current, and both transmitted and received optical power. DDMI information can be accessed in iView2.
AutoCross Feature
The 10/100BaseT Ethernet port on the IE-iMcV-E1-Mux/4 includes an AutoCross feature that automatically selects between a crossover workstation and a straight- through connection depending on the connected device.