IMC Networks iMediaChassis/3, 20, iMediaChassis/6 operation manual Reset Alarm Switch

Page 6

Reset Alarm Switch

When one power supply module malfunctions, an audible alarm sounds indicating the loss of the power module. The alarm can be silenced by pressing the Reset Alarm switch, located next to the power connector on the power supply module. If this occurs, remove and replace the power supply module immediately. (LEDs on the Management Module and the power supply module itself also indicate power supply module failures.)

Last Gasp Alarm

The iMediaChassis series includes the Last Gasp trap feature, “Remote Chassis Down”, which sends a Trap when the following occurs:

Both power supply modules malfunction

Both power supply modules are powered down

When the AC line fails

Temperature Gauge

The iMediaChassis/20 includes a temperature monitoring gauge with a heat sensor on the backplane of the chassis. Users define a threshold for chassis temperature via SNMP. If the chassis’ temperature rises above the specified level, the SNMP agent sends a trap (configured in iView²) to the administrator. There is also an LED indicator on the SNMP Management Module for chassis temperature.

SNMP Write Lock

There is an SNMP Write Lock switch located below slot #3 on the front of the iMediaChassis/20. The SNMP Write Lock switch prevents a new management board from re-configuring the application module settings

(e.g., the status of features such as LinkLoss, FiberAlert, Force mode, etc.) made via SNMP on any previous Management Modules.

NOTE

Leave this switch in the NORMAL position during day-to-day operation; the LOCKED position should only be used when changing the SNMP management board.

2

Image 6
Contents IMediaChassis series Warranty FCC Radio Frequency Interference StatementTable of Contents Safety Certifications IMediaChassis/20 Features About the iMediaChassis/20Reset Alarm Switch LNK/ACT FDX/COL Temp FAN a / FAN B Installing the iMediaChassis/20 Wiring Instruction Guidelines for iMediaChassis/20-2DC Installing Snmp Management and Application Modules Replacing Power Supply Modules User-Replaceable Power Supply ModulesDo not mix AC and DC power supply modules IMediaChassis/20 Specifications Input SpecificationsIMediaChassis/6 Features About the iMediaChassis/6LNK/ACT Installing the iMediaChassis Installing Management and Application Modules DC Power Wiring, Replacing Power Supply Modules and Fans IMediaChassis/6 Specifications IMediaChassis/3 Features About the iMediaChassis/3Installing the iMediaChassis/3 Snmp Write Lock Glows yellow when temperature of unit IMediaChassis/3 Specifications Hardware Feature Matrix Electrostatic Discharge Precautions IMC Networks Technical SupportSafety Certifications IMediaChassis/20 2006/95/EC iMediaChassis/6 and 3 73-23-EECDocument Number 50-80954-01 A0