Magnum | Installation and User Guide (12/02) |
longer distances, about 20Km with the
The same procedures as for
3.2.5Power Budget Calculations for P62-Series Fiber Media
Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget. To calculate the power budget of different fiber media installations using Magnum products, the following equations should be used:
OPB (Optical Power Budget) = PT(min) - PR(min)
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss) Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
where the “Cable Loss” for 62.5/125 and 50/125∝ m (m.m.) is 2.8 dB/km, and the “Cable Loss” for 100/140
The following data has been collected from component manufacturer’s (HP’s and Siemens’) web sites and catalogs to provide guidance to network designers and installers.
Fiber | Speed, |
| Std. km | Wave- | Cable | X’mitr | R’cvr | Worst | Worst* |
| typical | typical* |
Port | Std. | Mode | fdx | length | Size | Output | Sens. | OPB, | distance |
| OPB, | distance |
Module |
| (hdx) | nm | ∝ m | PT , dB | PR ,dB | dB | Km, fdx |
| dB | Km, fdx | |
|
|
| ||||||||||
P62- | 100Mb | Multi- | 2 | 1300 | 62.5/125 | 9.0 | 2.5 |
| 14 | 5 | ||
xMSC | FX | mode | (0.4) |
| 50/125 | 5.5 | 2.0 |
| 12 | 4 | ||
P62- | 100Mb | Single- | 20 | 1300 | 9/125 | 14 | 28 |
| 17.5 | 35 | ||
xSSC | FX | mode | (0.4) |
| ||||||||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| |
“Long | 100Mb | Single- | 40 | 1300 | 9/125 | 27 | 54 |
| 32.5 | 65 | ||
FX | mode |
| ||||||||||
Reach” | (0.4) |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Note: The use of either
•The 100Mb fiber segment must operate in
•The
Attenuation.
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
www . GarrettCom . com
23