GarrettCom P62F manual Power Budget Calculations for P62-Series Fiber Media, Km, fdx

Page 27

Magnum P62-Series Hardened Switches

Installation and User Guide (12/02)

longer distances, about 20Km with the single-mode SC.

The same procedures as for multi-mode fiber apply to single-mode fiber connectors. Follow the steps listed in Section 3.2.2 above.

3.2.5Power Budget Calculations for P62-Series Fiber Media

Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget. To calculate the power budget of different fiber media installations using Magnum products, the following equations should be used:

OPB (Optical Power Budget) = PT(min) - PR(min)

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss) Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

where the “Cable Loss” for 62.5/125 and 50/125∝ m (m.m.) is 2.8 dB/km, and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

The following data has been collected from component manufacturer’s (HP’s and Siemens’) web sites and catalogs to provide guidance to network designers and installers.

Fiber

Speed,

 

Std. km

Wave-

Cable

X’mitr

R’cvr

Worst

Worst*

 

typical

typical*

Port

Std.

Mode

fdx

length

Size

Output

Sens.

OPB,

distance

 

OPB,

distance

Module

 

(hdx)

nm

m

PT , dB

PR ,dB

dB

Km, fdx

 

dB

Km, fdx

 

 

 

P62-

100Mb

Multi-

2

1300

62.5/125

-20

-31

9.0

2.5

 

14

5

xMSC

FX

mode

(0.4)

 

50/125

-23.5

-31

5.5

2.0

 

12

4

P62-

100Mb

Single-

20

1300

9/125

-15

-31

14

28

 

17.5

35

xSSC

FX

mode

(0.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Long

100Mb

Single-

40

1300

9/125

-5

-34

27

54

 

32.5

65

FX

mode

 

Reach”

(0.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the following factors are both applied:

The 100Mb fiber segment must operate in full-duplex (FDX) mode, and

The worst-case OPB of the fiber link must be greater than the fiber cable’s passive

Attenuation.

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

www . GarrettCom . com

23

Image 27 Contents
Installation and User Guide Trademarks Hardened Ethernet Switches Installation and User GuideContacting GarrettCom, Inc GarrettCom, IncPersonal Switches, 10/100Mb Stackable Hubs, Snmp OptionalPersonal Hubs, 10Mb series Table of Contents Maximum Ethernet Segment or Domain Lengths SpecificationsTechnical Specifications Ports Performance Network StandardsMechanical Power Supply Internal 24VDC and -48VDC Power SupplyLED Indicators Fiber Ports # 1Mtbf Bellcore method Agency Approvals Parts Ordering InformationManaged P62-Series mP62 Hardened Switches Inspecting the Package and Product IntroductionProduct Description Www . GarrettCom . com Www . GarrettCom . com Managed Network Software MNS-mP for Magnum mP62 Console port Connecting the Console Terminal to Magnum mP62 ManagementFrame Buffering and Latency Fiber port, SC ConnectorsWww . GarrettCom . com Managed mP62’s with MNSmP software for Managed network Two future-proof fiber ports with SC connectorsTop-mounted LEDs for convenient viewing 24VDC and -48VDC Int. & 125V/250VDC ext. through PSX-TApplications Example Example 3. Magnum mP62 Mounting position and materials InstallationLocating Magnum P62F-Series 10/100Mb Ethernet Switches Mounting dimensionsMounting Hole Dimensions, inches & cm Media Ieee Standard Connecting Ethernet Media, and Special Strain-relief featureConnecting Fiber Optic SC-type, Snap-In Connecting Fiber Optic ST-type, Snap-In OptionalConnecting Single-Mode Fiber Optic Km, fdx Power Budget Calculations for P62-Series Fiber MediaP62 -48V, 24VDC Installation DC Power Terminals +, -,internally floatingPower the P62-5V w/DC Pwr Supply PSX-T at 125/250 VDC Power the P62-5V models w/Ext AC Power Supply PSX-APower Output 5VDC, 3Amps Power Capacity 15 wattsOperating Shock Cable Strain Relief Feature on all P62-Series models Operation Dual-Speed Functionality, and SwitchingSwitching, Filtering and Forwarding Switching, Address LearningAuto-negotiation and Speed-sensing LED’s for P62-Series Hardened SwitchBefore Calling for Assistance TroubleshootingReturn Material Authorization RMA Procedure When Calling for AssistanceAppendix a Warranty Information No Problem FoundShipping and Packaging Information