GarrettCom Magnum ST80 Technical Specifications Performance, Maximum Ethernet Segment Lengths

Page 6

Stackable Personal Hubs

Installation and User Guide (04/01)

1.0SPECIFICATIONS

1.1.Technical Specifications

Performance:

Data Rate: 10 Mbps

Partitioning: Enforced after 32 consecutive collisions.

Reconnect: Occurs after 512 bits error-free transmission.

Maximum Ethernet Segment Lengths:

 

10BASE-T (Unshielded twisted pair)

- 100 m (328 ft)

10BASE-T (Shielded twisted pair) - 150m (492 ft)

AUI Drop Cable

- 50 m (164 ft)

10BASE2 ThinNet (BNC)

- 185 m (607 ft)

10BASE5

- 500 m (1,640 ft)

10BASE-FL multi-mode Fiber optic

- 2 km (6562 ft)

Network Standards:

Ethernet V1.0/2.0 IEEE 802.3: 10BASE-T, 10BASE5, 10BASE2, 10BASE-FL, FOIRL.

(Magnum Stackable Personal Hubs are physical layer standard Ethernet products, and operate in networks independently of all software.)

Operating Environment:

Ambient Temperature: 32ºF to 122ºF (0ºC to 50ºC)

Storage Temperature: -20ºC to 60ºC

Ambient Relative Humidity: 10% to 95% (non-condensing)

Power Supply (External):

Input:

95 - 125 vac at 60 Hz for "-d" Models,

 

200 - 250 vac at 50 Hz for "-i" Models, which have

 

IEC power cable connector in the external power unit.

Output: 12 VDC, 1 A

Polarity: center positive, shell negative

Power Consumption: 12 watts max.

Connectors:

ST80: Eight shielded RJ-45 ports (one with up-link switch); one rear AUI, female, with slide lock; two Inter-Repeater-Bus connectors on the side.

ST80-B: Same as ST80, plus one rear BNC with internal termination switch.

ST80-F: Same as ST80, plus one rear Fiber ST-type.

(Shielded 10BASE-T connectors accept either unshielded or shielded wiring plugs for standard twisted pair media wiring.)

The regular RJ-45 ports support the standard for hubs-to-users twisted pair wiring: pin 1= receive+, 2 = receive-, 3 = transmit+, 6 = transmit-, other pins not used. The RJ-45 port with the up-link switch is normally the same, but when switched it supports the standard for up-links using twisted pair wiring, i.e., the transmit and the receive pairs are exchanged: pin 1 = transmit+, 2 = transmit-, 3 = receive+, 6 = receive- , other pins not used.

www . GarrettCom . com

1

Image 6
Contents Personal Hub Personal Hub TrademarksGarrettCom, Inc Contacting GarrettCom, IncInstallation Table of ContentsMagnum Line Connectors Technical Specifications PerformancePower Supply External Maximum Ethernet Segment LengthsWeight SwitchesDimensions WarrantyOrdering Information Model DescriptionIntroduction Inspecting the Package and ProductProduct Description NetworkPort Connectors Stack Enable Switch IRBStackable Personal Hubs Installation and User Guide 04/01 LEDs Simplify Network Installation and Maintenance Features and Benefits Expandable DesignInstallation Versatility Low cost, stand-alone 10BASE-T connectivityTo existing network via switchable Up-Link port ApplicationsFiber backbone Connection LED will Illuminate Power Jack InstallationPower Supply ExternalWall or Vertical Surface Mounting for non-stacked units only Combining and Mounting Stacked UnitsTwisted Pair Segment Connections AUI ConnectionAUI Pin Assignments Function ShellBNC Connection Model ST80-B only Fiber Optic Connection Model ST80-F onlySwitchable Up-Link Feature Stacking the ST80 Personal HubsIncreased port capacity via stacking Switch in X position Cascading the ST80 Personal Hub with the Up-Link portFunctional Operation, Use of LED Indicators OperationUsing the Up-Link switch Using the BNC Internal Termination Switch Model ST80-B onlyUsing the Stack Enable switch Troubleshooting Before Calling for AssistanceReturn Material Authorization RMA Procedure When Calling for AssistanceNo Problem Found Shipping and Packaging Information