Magnum 6KM Mobile Ethernet Switch Installation and User Guide | 07/10 |
3.4Powering the Magnum DC 6KM Mobile Ethernet Switches
The DC internal power supply supports installation environments where the DC voltage is from 10 to 300 volts, depending on the 6KM model selected. The power consumption will range from about 10 up to 15 watts, depending on the port quantity and types in the configuration. When connecting the Ethernet cabling, there is no need to power down the unit. Individual cable segments can be connected or disconnected without concern for
DC power input options are available to suit the 6KM Mobile Ethernet Switches to special
*12VDC,
*12VDC,
*AC input with internal power supply
(see Section 1.2, for Ordering Information)
Fig 3.4a
Single DC power input
Power input connection made with RD 24
(See Appendix B for more information)
Fig 3.4b
Dual-Source DC power input
Power input connection made with RD 24
(See Appendix C for more information)
Fig 3.4c
AC power input
Power input connection made with RD 24
(See Appendix D for more information)
www . GarrettCom . com
19