3.4Powering the Magnum DC 6KM Mobile Ethernet Switches

The DC internal power supply supports installation environments where the DC voltage is from 10 to 300 volts, depending on the 6KM model selected. The power consumption will range from about 10 up to 15 watts, depending on the port quantity and types in the configuration. When connecting the Ethernet cabling, there is no need to power down the unit. Individual cable segments can be connected or disconnected without concern for power-related problems or damage to the unit.

DC power input options are available to suit the 6KM Mobile Ethernet Switches to special high-availability communications and/or heavy industrial-grade applications, including:

*12VDC, -48VDC, 24VDC, 110VDC, 125VDC and 250VDC with single DC input,

*12VDC, -48VDC, 24VDC, 110VDC, 125VDC and 250VDC with dual DC input

*AC input with internal power supply

(see Section 1.2, for Ordering Information)

Fig 3.4a

Single DC power input

Power input connection made with RD 24 4-position (male) locking connector, +, -, NC, NC (Not connected)

(See Appendix B for more information)

Fig 3.4b

Dual-Source DC power input

Power input connection made with RD 24 4-position (male) locking connector, A+,A -, B-, B+

(See Appendix C for more information)

Fig 3.4c

AC power input

Power input connection made with RD 24 4-position (male) locking connector, +, -, GND, NC (Not connected)

(See Appendix D for more information)

www . GarrettCom . com

19

Image 24
Contents Mobile Ethernet Switch GarrettCom, Inc Contacting GarrettCom, IncElectrical Safety requirements Canadian Emissions StatementSpecifications Troubleshooting Specifications Technical Specifications PerformanceNetwork Standards and Compliance, hardware Maximum 10 Mbps Ethernet Segment LengthsCopper 10/100Mb connector types supported Copper 1000Mb connector types supportedFiber Multi-mode connector types supported Fiber Single-mode connector types supportedPower Consumption Dual -Source DC Power Input OptionalManagement Console connector Configuration Options see following pages Ordering InformationOptions and Extras Introduction Inspecting the Package and ProductProduct Description Magnum 6KM Mobile Ethernet Switch Packet Prioritization, 802.1p QOS Frame Buffering and Flow ControlWeb-browser, at ftp//ftp.garrettcom.com Managed Network Software for Magnum 6KMFeatures and Benefits „ M12 Copper connections „ Managed switching for high performance Ethernet LANs„ Fiber Ports Built-In „ MNS-6K-SECURE optional, for extra security Installation Connecting Ethernet Media Connecting Twisted Pair for 10/100Mb CAT3, CAT5, UTP or STPMedia Ieee Standard Www . GarrettCom . com Connecting Fiber Optic Cable to LC ports Mounting Dimensions for 6KM with metal brackets DIN-Rail Mounting the Magnum 6KM00 x 9.58 inches 10.20 x 24.33 cm center-to-center Panel / Wall Mounting position Powering the Magnum DC 6KM Mobile Ethernet Switches Single DC power inputDual-Source DC power input AC power input5a Alarm Contacts Connecting the Console Terminal to Magnum 6KM M12 6KM Console Port connector1 M12 Console Port pin assignments Switching Functionality OperationFiltering and Forwarding Address LearningAuto-CrossMDIX and Auto-negotiation, for M12 ports Flow-control, Ieee 802.3x standard Power Budget Calculations for 6KM Modules with Fiber Media Magnum 6KM Mobile Ethernet Switch Port Modules6KM Modules Blinking = Activity LC 100Mb Fiber port, 2 LED per port LEDOn = Link established Blinking = Activity LED6KM4-4M12, 4 x 10/100Mb M12 Slot C 3 P6KM4-4M12, 4 x PoE M12 Slot C PoE LEDs Summary6KM4-4MLC, 4 x Multimode LC Slot C 5 6KM4-4SLC, 6KM4-4SLCL, 4 x Singlemode LC Slot C6KM-2GM12, 2 x Gigabit M12 Slot B 7 6KM-2GMLC, 2 x Gigabit Multimode LC Slot B8 6KM-2GSLC, 6KM-2GSLCL, 2 x Gigabit Singlemode LC Slot B Troubleshooting When Calling for AssistanceBefore Calling for Assistance Return Material Authorization RMA Procedure No Problem FoundAppendix a Warranty Information Shipping and Packaging InformationFig B1.0a Location of chassis ground Power Consumption B3.0 6KM DC Single Source Installation Standard 6KM male DC Power Input connectorB4.0 UL Requirements for DC-powered units B5.0 TroubleshootingAppendix C DC Dual Source Power Input C4.0 Features and Benefits of the DUAL-SOURCE Design C5.0 6KM Dual Source InstallationC2.0 Magnum 6KM, with DC Dual-Source option C3.0 DUAL-SOURCE OPTION, Theory of OperationStandard 6KM Dual Source male DC Power Input connector C6.0 Ordering Information for Dual Source DC PowerExample Magnum 6KM-48VDC Dual-Src-48V Standard 6KM male AC Power Input connector