GarrettCom MAGNUM 6KM manual C2.0 Magnum 6KM, with DC Dual-Source option

Page 44

Magnum 6KM Mobile Ethernet Switch Installation and User Guide

07/10

C2.0 MAGNUM 6KM, with DC Dual-Source option

The 6KM Switch models with the internal -48VDC, 12VDC, 24VDC, 110VDC, 125VDC and 250VDC Dual-Source power supply are designed for installations where a battery plant is the power source, and where two separate power sources are utilized in order to increase operational uptime and to simplify maintenance.

C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION

The Dual-Source DC power option is designed using diodes inside of the chassis on each DC power input line. A diode is placed in each of the four input lines (behind the four external power

connection terminals) so that power from an external source can only flow into the unit. This allows the unit to operate

whenever DC power is correctly

applied to either or both of the two inputs.

C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN

a)The Switch unit can receive power from either input, “A” or “B”. The hub will normally draw its power from the DC source with the highest voltage at a given time.

b)The Switch unit will not allow power to flow from a higher voltage input to a lower voltage input, i.e. the two DC power sources are not mixed together by the hub.

c)When one correct DC input is present, the Switch will receive power if the other DC input is absent, or even if it is connected with reverse polarity or shorted or grounded.

d)Reverse polarity connections, if they should accidentally occur on either input, will not damage the Switch or power supply internally (nor will it blow the fuse in the internal power supply) because of the blocking action of the diodes. This is true even if one input connection is reversed while the Switch is operating from the other source.

e)The Switch will not receive power (and will not work) when both inputs are simultaneously absent or are both incorrectly connected.

C5.0 6KM DUAL SOURCE INSTALLATION

This section describes the proper connection of the 12, 24, –48, 110, 125 and 250VDC dual source leads to the power input connector on the Magnum 6KM Switch.

The DC input connector on the Magnum 6KM Mobile Ethernet Switch is located on the left front of the unit. The power terminals are connected as shown below, and they are electrically floating inside the unit so that either may be grounded by the user if desired. The chassis is “earth” or ground (GND).

The mating power cable connection to the 6KM switch is made utilizing a RD24, locking, female connector. Simply align the keyed female connector to the 6KM male connector and twist the threaded lock to secure.

www . GarrettCom . com

39

Image 44
Contents Mobile Ethernet Switch GarrettCom, Inc Contacting GarrettCom, IncElectrical Safety requirements Canadian Emissions StatementSpecifications Troubleshooting Specifications Technical Specifications PerformanceNetwork Standards and Compliance, hardware Maximum 10 Mbps Ethernet Segment LengthsCopper 10/100Mb connector types supported Copper 1000Mb connector types supportedFiber Multi-mode connector types supported Fiber Single-mode connector types supportedManagement Console connector Power ConsumptionDual -Source DC Power Input Optional Configuration Options see following pages Ordering InformationOptions and Extras Introduction Inspecting the Package and ProductProduct Description Magnum 6KM Mobile Ethernet Switch Packet Prioritization, 802.1p QOS Frame Buffering and Flow ControlWeb-browser, at ftp//ftp.garrettcom.com Managed Network Software for Magnum 6KM„ Fiber Ports Built-In Features and Benefits „ M12 Copper connections„ Managed switching for high performance Ethernet LANs „ MNS-6K-SECURE optional, for extra security Installation Media Ieee Standard Connecting Ethernet MediaConnecting Twisted Pair for 10/100Mb CAT3, CAT5, UTP or STP Www . GarrettCom . com Connecting Fiber Optic Cable to LC ports Mounting Dimensions for 6KM with metal brackets DIN-Rail Mounting the Magnum 6KM00 x 9.58 inches 10.20 x 24.33 cm center-to-center Panel / Wall Mounting position Powering the Magnum DC 6KM Mobile Ethernet Switches Single DC power inputDual-Source DC power input AC power input5a Alarm Contacts 1 M12 Console Port pin assignments Connecting the Console Terminal to Magnum 6KMM12 6KM Console Port connector Switching Functionality OperationFiltering and Forwarding Address LearningAuto-CrossMDIX and Auto-negotiation, for M12 ports Flow-control, Ieee 802.3x standard 6KM Modules Power Budget Calculations for 6KM Modules with Fiber MediaMagnum 6KM Mobile Ethernet Switch Port Modules Blinking = Activity LC 100Mb Fiber port, 2 LED per port LEDOn = Link established Blinking = Activity LED6KM4-4M12, 4 x 10/100Mb M12 Slot C 3 P6KM4-4M12, 4 x PoE M12 Slot C PoE LEDs Summary6KM4-4MLC, 4 x Multimode LC Slot C 5 6KM4-4SLC, 6KM4-4SLCL, 4 x Singlemode LC Slot C8 6KM-2GSLC, 6KM-2GSLCL, 2 x Gigabit Singlemode LC Slot B 6KM-2GM12, 2 x Gigabit M12 Slot B7 6KM-2GMLC, 2 x Gigabit Multimode LC Slot B Before Calling for Assistance TroubleshootingWhen Calling for Assistance Return Material Authorization RMA Procedure No Problem FoundAppendix a Warranty Information Shipping and Packaging InformationFig B1.0a Location of chassis ground Power Consumption B3.0 6KM DC Single Source Installation Standard 6KM male DC Power Input connectorB4.0 UL Requirements for DC-powered units B5.0 TroubleshootingAppendix C DC Dual Source Power Input C4.0 Features and Benefits of the DUAL-SOURCE Design C5.0 6KM Dual Source InstallationC2.0 Magnum 6KM, with DC Dual-Source option C3.0 DUAL-SOURCE OPTION, Theory of OperationExample Magnum 6KM-48VDC Dual-Src-48V Standard 6KM Dual Source male DC Power Input connectorC6.0 Ordering Information for Dual Source DC Power Standard 6KM male AC Power Input connector