GarrettCom P80C manual Power Budget Calculations for P80F Fiber Media, Km, fdx

Page 21

Magnum P80F & P80C Personal Switches

Installation and User Guide (07/03)

The same procedures as for multi-mode fiber apply to single-mode fiber connectors. Follow the steps listed in Section 3.2.2 above.

3.2.5Power Budget Calculations for P80F Fiber Media

Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget. To calculate the power budget of different fiber media installations using Magnum products, the following equations should be used:

OPB (Optical Power Budget) = PT(min) - PR(min)

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss) Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

where the “Cable Loss” for 62.5/125 and 50/125µm (m.m.) is 2.8 dB/km, and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

The following data has been collected from component manufacturer’s (HP’s and Siemens’) web sites and catalogs to provide guidance to network designers and installers.

Fiber

Speed,

 

Std. km

Wave-

Cable

X’mitr

R’cvr

Worst

Worst*

 

typical

typical*

Port

Std.

Mode

fdx

length

Size

Output

Sens.

OPB,

distance

 

OPB,

distance

Module

 

(hdx)

nm

µm

PT , dB

PR ,dB

dB

Km, fdx

 

dB

Km, fdx

 

 

 

P80F-

100Mb

Multi-

2

1300

62.5/125

-20

-31

9.0

2.5

 

14

5

MST, MSC

FX

mode

(0.4)

 

50/125

-23.5

-31

5.5

2.0

 

12

4

P80F-SSC

100Mb

Single-

20

1300

9/125

-15

-31

14

28

 

17.5

35

 

FX

mode

(0.4)

 

 

 

 

 

 

 

 

 

P80F-MTRJ

100Mb

Multi-

2

1300

62.5/125

-20

-31

9.0

3.0

 

15.8

5.5

 

FX

mode

(0.4)

 

50/125

-23.5

-31

5.5

2.0

 

12.2

4.0

Long Reach

100Mb

Single-

40

1300

9/125

-5

-34

27

54

 

32.5

65

FX

mode

(0.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the following factors are both applied:

The 100Mb fiber segment must operate in full-duplex (FDX) mode, and

The worst-case OPB of the fiber link must be greater than the fiber cable’s passive

Attenuation.

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

3.2.6Connections to NICs which support Auto-Negotiation, RJ-45 ports

The copper ports of Magnum P80F and P80C Personal Switches will function properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast Link Pulse

www . GarrettCom . com

17

Image 21
Contents Magnum P80F & P80C Personal Switches Trademarks Contacting GarrettCom, Inc GarrettCom, IncMagnum Line Revisions Power Supply External Technical Specifications Ports PerformanceNetwork Standards Maximum Ethernet Segment or Domain LengthsLED Indicators External -48VDC Power Supply OptionalUp-Link, Port # 1 or 1SW PackagingOrdering Information Magnum P80F, 10/100 Personal Switch with a 100Mb Fiber PortProduct Description General Inspecting the Package and ProductFiber SC above Fiber ST aboveUp-link Port 1SW for Cascading Magnum P80C chassis with all RJ-45 Copper ports100Mbps Fiber port, ST-type mm Fiber port, ST or SC Connector for Model P80FFrame Buffering and Latency „ Top-mounted LEDs for convenient viewing Applications „ Up-Link on port # 1 for a high speed copper connectionExample 2. Magnum P80C Personal Switch100Mb Servers Workstations Locating Magnum P80F & P80C 10/00Mb Personal Switch Table-Top or Shelf MountingWall or vertical surface mounting Media Ieee Standard Connecting Ethernet MediaConnecting Fiber Optic ST-type, twist-lock Connecting Fiber Optic SC-type, Snap-InConnecting Single-Mode Fiber Optic Km, fdx Power Budget Calculations for P80F Fiber MediaPowering the Magnum P80F and P80C Dual-Speed Functionality, and Switching Switching, Filtering and ForwardingSwitching, Address Learning Auto-negotiation and Speed-sensing Full or Half Duplex, manual selection for P80F ModelsFull or Half Duplex, manual selection for P80C Models LED’s Up-link Port # 1 or 1SWUse with Media Converters Before Calling for Assistance TroubleshootingWhen Calling for Assistance Return Material Authorization RMA ProcedureShipping and Packaging Information No Problem Found