Magnum | Installation and User Guide (08/03) |
UL Requirements
The following must be adhered to in order to conform to UL requirements:
1.Minimum 18 AWG cable for connection to a Centralized DC power source.
2.Minimum 14 AWG cable for connection to earthing wiring.
3.Use only with Listed 10 A circuit breaker provided in building installation.
4.“Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.
5.Fastening torque of the lugs on the terminal block: 9 inch pound max.
a)Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block.
3.3.2Power the P62-5V models w/Ext AC Power Supply (PSX-A)
The rugged Magnum
Input Voltage:
63HZ,
AC Power Connector: IEC-type,
male recessed
Wiring Pin out (P62F-5V) Power
Adaptor:
Pin 1 " +ve voltage (white wire in the cable)
Pin 2 "
Power Output : 5VDC, 3Amps max
Input Fuse for overload and short protection: 3AG type, 0.5 Amp; spare is included
Power Capacity: 15 watts output, 70% min efficiency
Surge Protection: over 150 joules, with clamping at 800V 50A min.