![](/images/new-backgrounds/1192166/19216619x1.webp)
Manageable
PLEASE NOTE:
I.
II.
III.
LEARNING
After VLAN classification, the switch checks the <source MAC address, VLAN> pair in the switching database (SDB) to see whether the <source MAC address, VLAN> pair is known.
-If it is unknown, the switch inserts the <source MAC address, VLAN> into the SDB and learns the <source MAC address, VLAN>.
-If it is known, the switch checks the <source MAC address, VLAN> for a mis matched port ID. If the port ID associated with the <source MAC address, VLAN> pair in the SDB is different than the receiving port, the switch modifies the port ID in the SDB and modifies its management database (MDB) accordingly.
FILTERING
After learning the address, the switch checks:
-Whether the source port or destination port is in the forwarding state.
-Whether the source MAC address or destination MAC address is to be filtered.
-Whether the source port ID is the same as destination port ID.
If any of these conditions are met, the switch drops the receiving.
Otherwise, it continues with the forwarding process described below.
FORWARDING
During the forwarding process, the switch checks whether the <destination MAC address, VLAN> pair is unknown.
-If it is unknown, the switch floods the receiving frame to all ports in the VLAN, excluding the source port.
-If it is known, the switch forwards the receiving frame to the port associated with the <destination MAC address, VLAN> pair. At the same time, the switch ascertains the individual’s ports VLAN tagging and/or
User’s Manual | 6 |