GE DEH-40417 manual Astat -IBP Plus Service Instructions Logic Board Replacement

Page 6

ASTAT ®-IBP Plus Service Instructions

Logic Board Replacement

CAUTION: Always handle circuit boards by their edges and do not distort the parts on the circuit boards.

ATTENTION: Il faut toujours manipuler les plaques de circuits par leurs côtés et ne pas déformer les pièces sur les plaques de circuits.

1.Remove the ASTAT-IBP cover as described in steps 1–2 of Cover Removal and Replacement.

2.Unplug the two ribbon cables from the Logic Board, as shown in Figure 3.

3.Remove the four corner screws holding the Logic Board to the stand-offs below the Logic Board. Lift the Logic Board straight up to remove it, as illustrated in Figure 4.

4.Reassemble the Logic Board to the starter. With the display on the Logic Board at the upper left corner, place the board on the stand-offs. Reattach the four screws holding the Logic Board to the stand-offs.

5.Reattach the two ribbon cables. Ensure that the ribbon cable at the bottom of the ASTAT-IBP is fully seated on both circuit boards and that the ribbon cable does not interfere with or touch the cover.

6.Reinstall the plastic cover and the terminal connectors as described in steps 3–4 of Cover Removal and Replacement.

Screws

Logic Board

Unplug Cable

Power Supply

Ribbon

Board

Figure 3. Logic board and part locations.

Logic Board

Cable Ribbon

Figure 4. Removing the Logic Board.

2

Prices and data subject to change without notice.

Image 6
Contents Astat -IBP Plus Solid State Starters Page AS Used in this Publication Astat -IBP Plus Service Instructions Table of Contents Astat -IBP Plus Service Instructions Cover Removal and ReplacementAstat -IBP Plus Service Instructions Logic Board Replacement Location of the Power Supply Board Gate lead connections for sizes K, L, and Y Board Removing the SCR module Location of SCRs on size M, Z, N ASTAT-IBP Disconnecting the SCR load side Removing the busbar mounting bolt Forth several times to evenly distribute the grease on Astat -IBP Plus Service Instructions Troubleshooting Guide PCBAstat -IBP Plus Service Instructions Renewal Parts List QI3P,Q,R,SDPPage GE Industrial Systems