GE MDS 05-4558A01 manual Measure & Connect Primary Power, Review the Transceiver’s Configuration

Page 5

Step 3—Measure & Connect Primary Power

The DC input power to the transceiver must be within 10–30 Vdc and capable of continuously providing at least 2.5 Amperes. A power con- nector with screw-terminals is provided with each unit. Strip the wire leads to 6 mm (1/4 inch). Be sure to observe proper polarity as shown in Figure 2 with the positive lead (+) on the left side; negative on the right side.

Invisibleplaceholder

CAUTION

POSSIBLE

EQUIPMENT

DAMAGE

Figure 2. Power Connector

(Polarity: Left +, Right –)

The transceiver must be used with negative-ground sys- tems only. The power supply should be equipped with overload protection (NEC Class 2 rating), to protect against a short circuit between its output terminals and the radio’s power connector.

NOTE: Typically, it takes about 30 seconds for the transceiver to fully power up, and may take several minutes to associate with another unit, especially if GPS is required for time synchroni- zation.

Step 4—Review the Transceiver’s Configuration

There are two key settings that must be known before placing the unit into service:

Network NameCommon identifier used by all of the units, that are part of the same network. The Network Name must be pro- grammed to enable Remote units to associate with the Access Point unit. (Default name is MDS-Mercury.)

IP Address—Must be a unique address to allow for IP access through the LAN port or over-the-air. (Default is 192.168.1.1)

4

MDS Mercury Series Startup Guide

05-4558A01, Rev. C

Image 5
Contents MDS Mercury Series Contents Product Description Installation OverviewInstallation Steps Mount the Transceiver Install the AntennaReview the Transceiver’s Configuration Measure & Connect Primary PowerConfiguration MenuFrequency Control. The following modes Repeat above steps for each unit in the network Check for Normal Operation Connect the Data EquipmentAiming Directional Antennas Resetting to Factory Defaults Use with CautionMain Menu Menu SystemMGT System Menu Default VALUES/RANGE Installation Reference ChartProcedure Transmitter Power & Antenna Test Troubleshooting Using LEDs TroubleshootingLink LED Troubleshooting with the Menu System General SpecificationsTransmitter ReceiverApprovals Physical InterfaceProtocols ManagementTechnical Assistance GE MDS, LLC

MDS 05-4558A01 specifications

The GE MDS 05-4558A01 is a robust and versatile communication device designed primarily for industrial applications. This product is part of a larger line of GE MDS communication solutions that ensure reliable data transmission over various distances, making it a preferred choice for manufacturers and operators in sectors such as utilities, transportation, and various industrial settings.

One of the main features of the GE MDS 05-4558A01 is its ability to support multiple communication protocols. This adaptability allows integration into a variety of existing network setups, facilitating seamless connectivity and efficient data transfer. The device is equipped with advanced packet radio technology, which enhances its performance in noisy environments, a common challenge in industrial operations.

The GE MDS 05-4558A01 also boasts a high level of scalability. Users can easily expand their networks as their operational needs grow, ensuring that the communication infrastructure remains robust and future-proof. This scalability is crucial for industries that require both immediate and long-term data transmission solutions without significant reinvestment in new technologies.

In addition to its communication capabilities, the device features durable construction designed to withstand harsh environmental conditions. Its rugged design ensures reliability in extreme temperatures, humidity, and even exposure to dust and chemicals. This durability is coupled with a compact form factor, allowing for flexible installation in various locations and environments.

Another significant characteristic of the GE MDS 05-4558A01 is its low power consumption. Designed to operate efficiently, it minimizes energy usage while maintaining consistent performance. This feature is particularly important for remote installations where power resources may be limited.

The device also incorporates advanced security protocols to protect the integrity of transmitted data. By employing encryption techniques and secure authentication methods, the GE MDS 05-4558A01 ensures that sensitive information remains protected from unauthorized access.

Its user-friendly interface simplifies installation and management, enabling technicians to quickly configure and deploy the devices with minimal training. This ease of use is complemented by comprehensive technical support provided by GE, ensuring that users can maximize the performance of their communication infrastructure.

Overall, the GE MDS 05-4558A01 stands out for its integration of advanced technologies, robust features, and reliability, making it an exceptional choice for industries needing dependable and secure data communication solutions.